{"id":1074,"date":"2015-08-09T13:33:58","date_gmt":"2015-08-09T13:33:58","guid":{"rendered":"http:\/\/www.oxidationtech.com\/blog\/?p=1074"},"modified":"2015-08-11T19:55:51","modified_gmt":"2015-08-11T19:55:51","slug":"data-logging-ozone-levels-with-the-series-500","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/data-logging-ozone-levels-with-the-series-500\/","title":{"rendered":"Data Logging Ozone Levels with the Series-500"},"content":{"rendered":"<p>Ozone detection and measurement accurately is possible with the <a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/aeroqual-series-500.html\">Series-500 Gas Detector<\/a>.\u00a0 This data can also be logged easily with this device to review later, or for reporting purposes.<\/p>\n<figure style=\"width: 309px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/aeroqual-series-500.html\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"https:\/\/www.oxidationtech.com\/media\/catalog\/product\/cache\/5\/image\/1800x\/040ec09b1e35df139433887a97daa66f\/a\/e\/aeroqual_handheld_with_sensors.jpg\" alt=\"Series-500 Ozone Monitor\" width=\"309\" height=\"235\" \/><\/a><figcaption class=\"wp-caption-text\">Aeroqual Series-500 can be used with a variety of gas detection heads.<\/figcaption><\/figure>\n<p>The Series-500 from Aeroqual has the most user friendly and powerful data logging software in the industry.\u00a0 This great tool will allow for review and production of charts, or tables within the Aeroqual desktop software, or exporting to a spreadsheet format.<\/p>\n<p>The Series-500 has the capability to store data on it&#8217;s internal memory.\u00a0 A total of 8,188 data points can be recorded at time intervals from 1 minute to 30 minutes.\u00a0 This will allow for long term data storage on the device.\u00a0 Data logging intervals can be chosen from 1 minute, to any duration the user chooses.\u00a0 At 5-minute intervals the Series-500 can store data for over 28 days.<\/p>\n<p>Screen shot below shows the table and graph view available in the Aeroqual data logging software.\u00a0 User can choose either table or graph mode, and can choose timeframe to capture data from.<\/p>\n<p><a href=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/image\/Aeroqual_logged_data_-_graph_and_table.png\"><img loading=\"lazy\" decoding=\"async\" id=\"Series-500 data logging\" class=\"center fit\" title=\"data logging screenshot\" src=\"https:\/\/www.oxidationtech.com\/media\/wysiwyg\/image\/Aeroqual_logged_data_-_graph_and_table.png\" alt=\"s-500 data logging example\" width=\"310\" height=\"174\" \/><\/a><\/p>\n<p><em>Click image for larger view<\/em><\/p>\n<p>Screen below shows the Daily View mode.\u00a0 User can choose to show a summary of data showing each day&#8217;s summary of min, max, and average captured data.<\/p>\n<p><a title=\"S-500 data logging software showing daily log\" href=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/image\/Aeroqual_logged_data_-_daily_average.png\"><img loading=\"lazy\" decoding=\"async\" id=\"Gas sensong toxic gasses\" class=\"center fit\" title=\"Series-500 data logging graph and table views\" src=\"https:\/\/www.oxidationtech.com\/media\/wysiwyg\/image\/Aeroqual_logged_data_-_daily_average.png\" alt=\"Aeroqual Data logging software\" width=\"313\" height=\"175\" \/><\/a><em>Click image for larger view<\/em><\/p>\n<p>Screen below shows the monitor set-up that can be performed from the Aeroqual Software.\u00a0 Using this softwate the monitor can be plugged into the PC and set-up without having to access the monitor.\u00a0 This is useful for outdoor, or potentially remote monitoring stations.\u00a0 Monitor logging intervals, alarm, and relay set-points can all be changed from your PC.<\/p>\n<p><a title=\"Aeroqual Series-500 set-up\" href=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/image\/Aeroqual_monitor_set-up.png\"><img loading=\"lazy\" decoding=\"async\" id=\"Gas sensong toxic gasses\" class=\"center fit\" title=\"Aeroqual Series-500 set-up\" src=\"https:\/\/www.oxidationtech.com\/media\/wysiwyg\/image\/Aeroqual_monitor_set-up.png\" alt=\"Aeroqual Monitor set-up software\" width=\"318\" height=\"178\" \/><\/a><em>Click image for larger view<\/em><\/p>\n<p><strong>External Data Logger<\/strong><\/p>\n<p>Also available is an external data logger in the event the Series-500 must remain stationary while data is retrieved and brought to another location.\u00a0\u00a0 For these purposes we supply the DL-3 data logger.<\/p>\n<p>Using the 0-5 VDC output signal from the S-500 the DL-3 can log and save gas measurements.\u00a0 This handy device is compact and simply unplugs from the cord and can be taken back to the office to download and record the data.<\/p>\n<div class=\"halflings-icon-list ok-circle \"><\/div>\n<div class=\"halflings-icon-list ok-circle \"><a title=\"DL-3 Data Logger\" href=\"https:\/\/www.gas-sensing.com\/accessories\/dl-3.html\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.gas-sensing.com\/media\/catalog\/product\/cache\/1\/small_image\/210x\/9df78eab33525d08d6e5fb8d27136e95\/d\/l\/dl-3.png\" alt=\"DL-3 Ecosensors data logger\" width=\"142\" height=\"142\" \/><\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Ozone detection and measurement accurately is possible with the Series-500 Gas Detector.\u00a0 This data can also be logged easily with this device to review later, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"aside","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[62],"tags":[181,349,351,352,73,350],"class_list":["post-1074","post","type-post","status-publish","format-aside","hentry","category-ozone-products","tag-aeroqual-ozone-meter","tag-aeroqual-s-500","tag-kanomax-ozone","tag-kanomax-s500","tag-ozone-monitor","tag-series-500-ozone","post_format-post-format-aside"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/1074","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=1074"}],"version-history":[{"count":2,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/1074\/revisions"}],"predecessor-version":[{"id":1079,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/1074\/revisions\/1079"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=1074"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=1074"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=1074"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}