{"id":1444,"date":"2016-09-15T02:38:16","date_gmt":"2016-09-15T02:38:16","guid":{"rendered":"http:\/\/www.oxidationtech.com\/blog\/?p=1444"},"modified":"2016-09-12T02:47:05","modified_gmt":"2016-09-12T02:47:05","slug":"preventative-maintenance-services","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/preventative-maintenance-services\/","title":{"rendered":"Preventative Maintenance Services"},"content":{"rendered":"<p>Oxidation technologies offers <a href=\"https:\/\/www.oxidationtech.com\/services\/maintenance.html\">preventative maintenance services <\/a>for almost all industrial and commercial ozone equipment.\u00a0 Our staff can go on-site check equipment, perform maintenance and ensure reliable long term maintenance of your equipment.<\/p>\n<p>All mechanical equipment requires maintenance of some sort.\u00a0 Why not have the ozone experts check your system at least once a year?<\/p>\n<h2><span style=\"color: #3366ff;\"><strong>Ozone System <a href=\"https:\/\/www.oxidationtech.com\/services\/maintenance.html\">Preventative Maintenance Services:<\/a><\/strong><\/span><\/h2>\n<ul>\n<li>Even the best systems require maintenance<\/li>\n<li>Poorly maintained ozone systems produce poor results<\/li>\n<li>Ozone system maintenance can be simple if it is performed regularly<\/li>\n<li>Feed gas systems are commonly neglected<\/li>\n<li>Ozone leak sensors require calibration<\/li>\n<li>Some corona cells require cleaning<\/li>\n<li>Check valve and water traps must be in working condition<\/li>\n<li>If neglected, repairs will cost far more than routine maintenance<\/li>\n<\/ul>\n<h2><span style=\"color: #3366ff;\"><strong>Ozone Generator\/System Service:<\/strong><\/span><\/h2>\n<ul>\n<li>We can perorm on-site service of your integrated system as needed or set-up a contract<\/li>\n<li>We offer monthly, quarterly, bi-annually, and annual service contracts<\/li>\n<li>Proper service and maintenance is required for long lasting equipment<\/li>\n<li>Many times preventative maintenance will cost less than costly repairs<\/li>\n<\/ul>\n<p><em><a title=\"ozone system repair and service\" href=\"https:\/\/www.oxidationtech.com\/services\/repair.html\">Click HERE to be directed to our ozone system repair\/service webpage.<\/a><\/em><\/p>\n<p><em>For details on your ozone generator or ozone system components please <a title=\"contact oxidation technologies\" href=\"https:\/\/www.oxidationtech.com\/contact-us\">Contact Us<\/a>, we would be glad to help you design a PM plan for your equipment.<\/em><\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #3366ff;\"><strong>List of common ozone generator brands we have offered maintenance service for:<\/strong><\/span><\/h3>\n<ul>\n<li>Ozonia<\/li>\n<li>Wedeco<\/li>\n<li>Plasma Technics (PTI)<\/li>\n<li>Azcozon<\/li>\n<li>Absolute Ozone<\/li>\n<li>Hess Machine<\/li>\n<li>Pacific Ozone<\/li>\n<li>Clearwater Tech<\/li>\n<li>Del Ozone<\/li>\n<li>Welsbach<\/li>\n<li>Polymetric<\/li>\n<li>Ozotech<\/li>\n<\/ul>\n<p><span style=\"color: #3366ff;\">\u00a0<\/span><span style=\"color: #3366ff;\"><b>List of supporting ozone equipment we commonly offer maintenance service for:<\/b><\/span><\/p>\n<ul>\n<li><span style=\"color: #339966;\"><strong>Oxygen Concentrators<\/strong><\/span>\n<ul>\n<li>OGSI<\/li>\n<li>Air Sep<\/li>\n<li>Sequal<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #339966;\"><strong>Air Dryers<\/strong><\/span>\n<ul>\n<li>PureGas<\/li>\n<li>Ingersoll Rand<\/li>\n<li>Azco<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #339966;\"><strong>Air Compressors<\/strong><\/span>\n<ul>\n<li>Ingersoll Rand<\/li>\n<li>Kaiser<\/li>\n<li>Gast<\/li>\n<li>Thomas<\/li>\n<\/ul>\n<\/li>\n<li><strong><span style=\"color: #339966;\">Ozone Monitor<\/span><br \/>\n<\/strong><\/p>\n<ul>\n<li>Eco-Sensors<\/li>\n<li>Analytical Technologies, Inc. (ATI)<\/li>\n<li>Aeroqual<\/li>\n<li>Teledyne API<\/li>\n<li>2B Tech<\/li>\n<li>BMT<\/li>\n<li>IN-USA<\/li>\n<\/ul>\n<\/li>\n<li><span style=\"color: #339966;\"><strong>Accessories<\/strong><\/span>\n<ul>\n<li>Rebuild injection pump<\/li>\n<li>Rebuild\/replace check valves<\/li>\n<li>Replace venturi<\/li>\n<li>Check for proper air vent operation<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li><span style=\"color: #339966;\">A little humor:<\/span>\n<p><em>Top 10 reasons ozone systems are not maintained<\/em><\/p>\n<ol>\n<li><em>We can&#8217;t find\/lost the manual<\/em><\/li>\n<li><em>The manufacturer didn&#8217;t send the manual<\/em><\/li>\n<li><em>Ozone? I heard that stuff was dangerous!<\/em><\/li>\n<li><em>I don&#8217;t go near anything more than 500 volts<\/em><\/li>\n<li><em>I don&#8217;t think ozone really does anything anyway, after all our water is fine isn&#8217;t it?<\/em><\/li>\n<li><em>It started leaking a few months ago, we couldn&#8217;t find the leak, so we just shut it off<\/em><\/li>\n<li><em>The manual didn&#8217;t say anything about maintenance, did it?<br \/>\n<\/em><\/li>\n<li><em>I don&#8217;t even know why we have that thing, no one asked me if it was a good idea!<\/em><\/li>\n<li><em>What does ozone do anyway?<\/em><\/li>\n<li><em>The last time I worked on it I inhaled way too much ozone, I&#8217;m not doing that again!<\/em><\/li>\n<\/ol>\n<p>Summary: don&#8217;t let this be you!<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Oxidation technologies offers preventative maintenance services for almost all industrial and commercial ozone equipment.\u00a0 Our staff can go on-site check equipment, perform maintenance and ensure [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"aside","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[3],"tags":[664,663,111],"class_list":["post-1444","post","type-post","status-publish","format-aside","hentry","category-tech-tips","tag-ozone-generator-maintenance","tag-ozone-preventative-maintenance","tag-ozone-system-maintenance","post_format-post-format-aside"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/1444","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=1444"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/1444\/revisions"}],"predecessor-version":[{"id":1445,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/1444\/revisions\/1445"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=1444"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=1444"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=1444"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}