{"id":395,"date":"2014-12-03T16:09:58","date_gmt":"2014-12-03T16:09:58","guid":{"rendered":"http:\/\/ozone-services.com\/?p=395"},"modified":"2014-12-03T16:09:58","modified_gmt":"2014-12-03T16:09:58","slug":"uv-1-oem-ozone-analyzer","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/uv-1-oem-ozone-analyzer\/","title":{"rendered":"UV-1 OEM Ozone Analyzer"},"content":{"rendered":"<h1><a title=\"UV-1 Ozone Photometer\" href=\"https:\/\/www.gas-sensing.com\/fixed-mount-monitors\/uv1-ozone-analyzer.html\"><span style=\"color: #0000ff;\">UV Ozone Photometer OEM Module<\/span><\/a><\/h1>\n<p>The Aeroqual UV-1 Ozone Photometer Module is designed for measurement and control of ozone in the range 0-200 ppm using a single beam UV photometer. It has a folded metal enclosure designed to be built into an ozone treatment system. The UV- 1 offers advanced monitoring and control.<\/p>\n<p>Most ozone measuring devices used industrially today are based on electrochemical, or Heated Metal Oxide (HMOS) sensor technologies.\u00a0 While these are reliable, and easy to use, they are also cross-sensitive to many other gasses in the atmosphere or industrial settings.\u00a0 Due to the UV light used in a UV Analyzer there is no cross sensitivity to these gasses.<\/p>\n<figure style=\"width: 320px\" class=\"wp-caption alignnone\"><a title=\"UV-1 Ozone Photometer\" href=\"https:\/\/www.gas-sensing.com\/fixed-mount-monitors\/uv1-ozone-analyzer.htmlhttp:\/\/\"><img loading=\"lazy\" decoding=\"async\" id=\"image\" title=\"UV-1 Ozone Analyzer\" src=\"https:\/\/www.gas-sensing.com\/media\/catalog\/product\/cache\/1\/image\/9df78eab33525d08d6e5fb8d27136e95\/u\/v\/uv-1_photometer.jpg\" alt=\"UV-1 Ozone Analyzer\" width=\"320\" height=\"212\" \/><\/a><figcaption class=\"wp-caption-text\">UV-1 Ozone Photometer &#8211; $2,890<\/figcaption><\/figure>\n<h2><span style=\"color: #0000ff;\"><strong>Benefits<\/strong><\/span><\/h2>\n<ul>\n<li>Wide ozone measurement range 0-200 ppm ozone measurement range<\/li>\n<li>Minimal sensitivities to other gasses.<\/li>\n<li>Capable of remote sampling due to integrated pump<\/li>\n<li>UV technology for improve measurement accuracy and stability<\/li>\n<li>Designed for integration into existing ozone treatment system<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" id=\"product-gallery-image\" class=\"image alignright\" src=\"https:\/\/www.gas-sensing.com\/media\/catalog\/product\/cache\/1\/image\/9df78eab33525d08d6e5fb8d27136e95\/u\/v\/uv-1_photometer.png\" alt=\"UV-1 Ozone Photometer Aeroqual\" width=\"149\" height=\"149\" \/><\/p>\n<h2><span style=\"color: #0000ff;\"><strong>Applications<\/strong><\/span><\/h2>\n<ul>\n<li>Ozone generator control in:\n<ul>\n<li>Cold storage applications where ethylene gas is present<\/li>\n<li>Odor control applications where gasses are oxidized by ozone<\/li>\n<li>Air treatment applications where ozone control is critical<\/li>\n<\/ul>\n<\/li>\n<li>Air purification systems<\/li>\n<li>Integration Module<\/li>\n<li>Ozone leak detection<\/li>\n<\/ul>\n<h2><span style=\"color: #0000ff;\">Features<\/span><\/h2>\n<ul>\n<li>Wide measurement range of ozone (0-200 ppm)<\/li>\n<li>Single-beam UV photometer<\/li>\n<li>Pump sampling via PTFE tubing (e.g. monitoring outside of a room or duct)<\/li>\n<li>Digital RS485 output (2 wire) or RS232<\/li>\n<li>Custom configuration upon request<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" id=\"product-gallery-image\" class=\"image alignnone\" src=\"https:\/\/www.gas-sensing.com\/media\/catalog\/product\/cache\/1\/image\/9df78eab33525d08d6e5fb8d27136e95\/u\/v\/uv-1_photometer_with_descriptions.jpg\" alt=\"UV-1 OEM Ozone Analyzer\" width=\"483\" height=\"302\" \/><\/p>\n<h2><a href=\"http:\/\/ozone-services.com\/wp-content\/uploads\/2014\/11\/UV-1-Brochure.pdf\">UV-1-Brochure<\/a><\/h2>\n<h2><a href=\"http:\/\/ozone-services.com\/wp-content\/uploads\/2014\/11\/UV-1-OEM-Module-User-Guide.pdf\">UV-1-OEM-Module-User-Guide<\/a><\/h2>\n<h2>\u00a0<img loading=\"lazy\" decoding=\"async\" id=\"product-gallery-image\" class=\"image alignnone\" src=\"https:\/\/www.gas-sensing.com\/media\/catalog\/product\/cache\/1\/image\/9df78eab33525d08d6e5fb8d27136e95\/u\/v\/uv-1_photometer_lid_off.jpg\" alt=\"UV based ozone analyzer\" width=\"600\" height=\"302\" \/><\/h2>\n<h2><a title=\"UV-1 Ozone Photometer\" href=\"https:\/\/www.gas-sensing.com\/fixed-mount-monitors\/uv1-ozone-analyzer.htmlhttp:\/\/\">Click here to purchase or learn more about the UV-1 Ozone Photometer<\/a><\/h2>\n","protected":false},"excerpt":{"rendered":"<p>UV Ozone Photometer OEM Module The Aeroqual UV-1 Ozone Photometer Module is designed for measurement and control of ozone in the range 0-200 ppm using [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[62],"tags":[113,114,115],"class_list":["post-395","post","type-post","status-publish","format-standard","hentry","category-ozone-products","tag-ozone-analyzer","tag-ozone-photometer","tag-ozone-uv-sensor"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/395","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=395"}],"version-history":[{"count":0,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/395\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=395"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=395"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=395"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}