{"id":4497,"date":"2024-04-16T09:00:00","date_gmt":"2024-04-16T14:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=4497"},"modified":"2024-04-09T09:50:04","modified_gmt":"2024-04-09T14:50:04","slug":"introducing-the-model-480l-a-revolutionary-uv-absorption-ozone-monitor","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/introducing-the-model-480l-a-revolutionary-uv-absorption-ozone-monitor\/","title":{"rendered":"Introducing the Model 480L: A Revolutionary UV Absorption Ozone Monitor"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">In the realm of ozone monitoring technology, precision, reliability, and ease of operation are paramount. Enter the Model 480L \u2013 a groundbreaking ozone monitor housed in a splashproof NEMA 4X wall mount enclosure. With the ability to monitor up to six individual sample streams, this monitor sets a new standard for performance, reliability, and versatility in ozone detection.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Unveiling the Model 480L<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The Model 480L ozone monitor has been meticulously designed to deliver exceptional performance, reliability, and simplicity of operation. Here&#8217;s what sets it apart:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>UV Absorption Method<\/strong>: Employing the UV absorption method based on the Beer-Lambert Law, the Model 480L offers accurate and reliable ozone measurement across a wide range of concentrations.<\/li>\n\n\n\n<li><strong>Mercury-Free UV LED Source<\/strong>: Breaking new ground in ozone monitoring technology, the Model 480L features a mercury-free UV LED source in the detection cell, making it the first of its kind in the industry. This innovation ensures environmental sustainability without compromising performance.<\/li>\n\n\n\n<li><strong>Built-In Diagnostics and Alarms<\/strong>: Equipped with built-in diagnostics, error logs, and warning alarms, the Model 480L provides real-time feedback on operating parameters. This proactive approach allows for timely intervention and ensures maximum uptime.<\/li>\n\n\n\n<li><strong>Modular Internal Design<\/strong>: The modular internal design of the Model 480L enhances field serviceability, making maintenance and repairs more straightforward and cost-effective.<\/li>\n\n\n\n<li><strong>Intuitive Graphical User Interface<\/strong>: Featuring an operator-friendly menu-driven software, the Model 480L allows for easy setup and configuration of operating parameters directly in the field.<\/li>\n\n\n\n<li><strong>Ethernet Connectivity<\/strong>: With Ethernet connectivity as standard and WiFi capability on the horizon, the Model 480L offers improved communication interfaces, enhancing productivity and flexibility in data management.<\/li>\n<\/ol>\n\n\n\n<h5 class=\"wp-block-heading\">Technical Specifications<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The Model 480L boasts impressive technical specifications, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Measurement Range: 0-1 ppm to 0-500 ppm<\/li>\n\n\n\n<li>Precision\/Repeatability: \u00b1 0.5% of full scale<\/li>\n\n\n\n<li>Accuracy: \u00b1 1% of full scale<\/li>\n\n\n\n<li>Lower Detectable Limit: 0.003 ppm<\/li>\n\n\n\n<li>Display Resolution: 0.001 ppm<\/li>\n\n\n\n<li>Response Time: &lt; 30 seconds to 95%<\/li>\n\n\n\n<li>Temperature Range: 5 &#8211; 45\u00b0C<\/li>\n\n\n\n<li>Power: 100-240VAC, 50\/60Hz, 74W<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\">Versatile Applications<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">With 1, 3, and 6 stream versions available, the Model 480L is suitable for a wide range of safety monitoring applications. Whether it&#8217;s for industrial settings, laboratory environments, or indoor air quality monitoring, the Model 480L offers unparalleled accuracy and reliability.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Conclusion<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">In conclusion, the Model 480L UV Absorption Ozone Monitor represents a paradigm shift in ozone monitoring technology. With its innovative features, cutting-edge UV LED source, and robust construction, the Model 480L sets a new standard for performance, reliability, and ease of operation. Whether for environmental compliance, process optimization, or safety monitoring, the Model 480L delivers unmatched precision and peace of mind.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.oxidationtech.com\/480l.html\" data-type=\"link\" data-id=\"https:\/\/www.oxidationtech.com\/480l.html\">https:\/\/www.oxidationtech.com\/480l.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In the realm of ozone monitoring technology, precision, reliability, and ease of operation are paramount. Enter the Model 480L \u2013 a groundbreaking ozone monitor housed [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":4498,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1244],"tags":[187,73],"class_list":["post-4497","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ozone-monitor","tag-ozone","tag-ozone-monitor"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=4497"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4497\/revisions"}],"predecessor-version":[{"id":4499,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4497\/revisions\/4499"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/4498"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=4497"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=4497"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=4497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}