{"id":4636,"date":"2024-06-12T09:00:00","date_gmt":"2024-06-12T14:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=4636"},"modified":"2024-06-11T09:47:30","modified_gmt":"2024-06-11T14:47:30","slug":"enhancing-oxo-style-oxygen-concentrators-with-advanced-timing-board","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/enhancing-oxo-style-oxygen-concentrators-with-advanced-timing-board\/","title":{"rendered":"Enhancing OXO-Style Oxygen Concentrators with Advanced Timing Board"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\"><\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">In the realm of medical devices, oxygen concentrators play a crucial role in delivering life-sustaining oxygen to patients with respiratory conditions. Ensuring the reliability and efficiency of these devices is paramount. One of the latest innovations enhancing OXO-style oxygen concentrators, specifically models OXO6, OXO8, and OXO10, is the replacement timing board equipped with O2 purity and pressure sensors. This upgrade not only maintains continuous operation but also offers real-time monitoring and alert systems to ensure optimal performance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Continuous Operation with Advanced Alerts<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A standout feature of the new timing board is its ability to prevent the concentrator from shutting down due to purity or pressure issues. Instead, the unit will remain operational, alerting users through a loud audible alarm. This design ensures that users are immediately aware of any issues without disrupting the supply of oxygen. The only scenarios that will shut down the concentrator are manually flipping the power switch, disconnecting the power cord or wiring harness, or tripping the circuit breaker\/thermal switch on the compressor.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">LED Indicators for Real-Time Performance Monitoring<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The upgraded 8400-1304 board includes intuitive LED indicators that provide real-time feedback on the concentrator\u2019s performance:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Green LED Indicators<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Flashing Green LED (Top LED):<\/strong> Indicates that the machine is on and currently building up its oxygen purity. This initial phase is crucial as the concentrator stabilizes its output for safe and effective use.<\/li>\n\n\n\n<li><strong>Solid Green LED:<\/strong> Illuminates once the unit has reached an oxygen purity level of at least 87%, signaling that it is ready for use. This threshold is essential for ensuring the oxygen delivered meets medical standards.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Yellow LED Indicators<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Flashing Yellow LED (Bottom LED; Alarm Function):<\/strong> Signifies a pressure issue within the system. The board\u2019s pressure sensor operates within a range of 4.0 \u2013 29.0 PSI. If the pressure deviates outside this range, the LED flashes, and an alarm sounds. This typically indicates a leak or a disconnected component, such as tubing.<\/li>\n\n\n\n<li><strong>Solid Yellow LED (Bottom LED; Alarm Function):<\/strong> Activates when the oxygen purity drops below 87%. This can result from various issues, including a low output compressor, leaks, disconnections, or problems with the sieve bed. The solid yellow light, combined with the audible alarm, prompts immediate investigation and resolution to maintain the concentrator\u2019s effectiveness.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The integration of an advanced timing board with O2 purity and pressure sensors in OXO-style oxygen concentrators represents a significant enhancement in patient care and device reliability. By ensuring continuous operation and providing real-time alerts through LED indicators and audible alarms, this innovation helps maintain the critical balance of purity and pressure essential for effective oxygen therapy. Users can have peace of mind knowing that their oxygen concentrator is equipped to promptly alert them to any issues while continuing to deliver the oxygen they need.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you\u2019re using the OXO6, OXO8, or OXO10 model, the addition of this advanced timing board is a vital upgrade that underscores the importance of precision and reliability in medical devices.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.oxidationtech.com\/oxo-timing-board-o2-purity.html\" data-type=\"link\" data-id=\"https:\/\/www.oxidationtech.com\/oxo-timing-board-o2-purity.html\">https:\/\/www.oxidationtech.com\/oxo-timing-board-o2-purity.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In the realm of medical devices, oxygen concentrators play a crucial role in delivering life-sustaining oxygen to patients with respiratory conditions. Ensuring the reliability and [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":4637,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1293],"tags":[1292,1289,1179,1291],"class_list":["post-4636","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-replacement-parts","tag-o2-purity","tag-oxygen-replacement-parts","tag-replacement-parts","tag-timing-board"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4636","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=4636"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4636\/revisions"}],"predecessor-version":[{"id":4638,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4636\/revisions\/4638"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/4637"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=4636"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=4636"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=4636"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}