{"id":4644,"date":"2024-06-17T08:00:00","date_gmt":"2024-06-17T13:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=4644"},"modified":"2024-06-17T11:49:48","modified_gmt":"2024-06-17T16:49:48","slug":"aeroqual-sensor-information","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/aeroqual-sensor-information\/","title":{"rendered":"Aeroqual Sensor Information"},"content":{"rendered":"\n<h2 class=\"wp-block-heading has-medium-font-size\">Aeroqual Sensor Technology<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Aeroqual is at the forefront of air quality monitoring technology, providing advanced sensors designed for precise and reliable gas and particulate matter measurements. Below is a detailed overview of the various sensor technologies developed by Aeroqual:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Technology:<\/td><td>Description:<\/td><\/tr><tr><td>GSS<\/td><td>Our&nbsp;<strong>gas sensitive semiconductor<\/strong>&nbsp;sensors use proprietary sensing material, built-in automatic baseline correction and interference rejection. This combination results in ppb resolution and a highly linear response.<\/td><\/tr><tr><td>GSE<\/td><td>Our&nbsp;<strong>gas sensitive electrochemical<\/strong>&nbsp;sensors generate nano-amp currents proportional to the gas concentration. Aeroqual uses low noise electronics to capture these signals resulting in low detection levels.<\/td><\/tr><tr><td>LPC<\/td><td><br>Our&nbsp;<strong>laser particle counter<\/strong>&nbsp;for particulate matter measurement uses optimized signal processing, low noise electronics and algorithms to correct for interferences, e.g. humidity.<\/td><\/tr><tr><td>NDIR<\/td><td>Our&nbsp;<strong>non-dispersive infra-red<\/strong>&nbsp;sensors use infra-red light, a narrow band-pass filter and photodiode to measure the intensity of light at the gas absorption band. The light intensity is proportional to the gas concentration.<\/td><\/tr><tr><td>PID<\/td><td>Our&nbsp;<strong>photo ionization detector<\/strong>&nbsp;sensors use a krypton filled UV lamp to ionize VOC gas molecules and generate a current that\u2019s proportional to the VOC concentration. The PID sensor responds to a wide range of VOCs and is industry recognized. The PID sensor uses is a 10.6 eV UV lamp that has a run time of 5000 lit hours. The operating life is up to 5 years.<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Please refer to this table to see the <a href=\"https:\/\/www.gas-sensing.com\/support\/aeroqual-sensor-information.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/support\/aeroqual-sensor-information.html\">sensor head images. <\/a><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2024\/06\/Untitled-design-1-1024x1024.png\" alt=\"\" class=\"wp-image-1654\" style=\"width:910px;height:auto\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Each sensor head features an inlet and outlet, ensuring efficient air sampling and accurate measurements. For detailed illustrations, refer to the <a href=\"https:\/\/d3t0tbmlie281e.cloudfront.net\/igi\/aeroqual\/WlHN6W1DPqpI5GHU.full\">sensor head design image<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/d3t0tbmlie281e.cloudfront.net\/igi\/aeroqual\/WlHN6W1DPqpI5GHU.full\" alt=\"\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">Sensor Accuracy<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Aeroqual&#8217;s sensors are renowned for their accuracy and reliability. For an in-depth look at sensor accuracy, refer to the <a href=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/aeroqual-sensors_1.png\">sensor accuracy chart<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/aeroqual-sensors_1.png\" alt=\"\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Aeroqual&#8217;s innovative sensor technologies and designs ensure precise, reliable, and user-friendly air quality monitoring solutions, making them a leader in the field. Whether for industrial, commercial, or personal use, Aeroqual sensors provide the accuracy and dependability needed for effective air quality management.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Aeroqual Sensor Technology Aeroqual is at the forefront of air quality monitoring technology, providing advanced sensors designed for precise and reliable gas and particulate matter [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":4645,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[211],"tags":[73],"class_list":["post-4644","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ozone-industry-news","tag-ozone-monitor"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4644","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=4644"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4644\/revisions"}],"predecessor-version":[{"id":4646,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4644\/revisions\/4646"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/4645"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=4644"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=4644"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=4644"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}