{"id":4655,"date":"2024-06-25T08:00:00","date_gmt":"2024-06-25T13:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=4655"},"modified":"2024-06-26T10:10:31","modified_gmt":"2024-06-26T15:10:31","slug":"sanitron-s2400c-ultraviolet-water-purification-system","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/sanitron-s2400c-ultraviolet-water-purification-system\/","title":{"rendered":"Sanitron S2400C Ultraviolet Water Purification System"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\"><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Overview<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The Sanitron S2400C Ultraviolet Water Purification System is a state-of-the-art solution for ensuring clean, safe water. Utilizing germicidal ultraviolet (UV) lamps, this system purifies water at an impressive rate of 40 gallons per minute without the need for heat or chemicals. Priced at $2,875.00, the S2400C offers a reliable, chemical-free method to keep your water free from harmful microorganisms.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Key Features<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Rapid Purification<\/strong>: Cleans 40 gallons per minute.<\/li>\n\n\n\n<li><strong>Chemical-Free<\/strong>: No added chemicals mean no risk of overdosing or unwanted taste and odors.<\/li>\n\n\n\n<li><strong>Immediate Use<\/strong>: Water is ready for use right after it exits the purifier.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">How UV Purification Works<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Ultraviolet radiation is highly effective against bacteria, viruses, and fungi. The germicidal UV lamps within the S2400C produce short-wave UV radiation that destroys harmful microorganisms in water. Here\u2019s a step-by-step breakdown of the process:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Water Entry<\/strong>: Water enters the purifier, flowing between the quartz-sleeved UV lamp and the chamber wall.<\/li>\n\n\n\n<li><strong>Even Exposure<\/strong>: A wiper system stirs the water to ensure uniform exposure to UV rays.<\/li>\n\n\n\n<li><strong>Ready Water<\/strong>: The purified water exits the other end, ready for immediate use.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">A translucent sight port allows you to check the operation of the germicidal lamp. If the lamp is working, its glow will be visible through the port.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Maintenance &amp; Installation<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Maintenance is straightforward with the Sanitron system. Designed for easy disassembly, no special tools are required to replace components. The end caps can be removed by hand, allowing new lamps or sleeves to be installed in minutes. For optimal performance, it\u2019s recommended to replace the lamp after 10,000 hours of use (approximately 14 months of continuous operation). The dual-action assembly permits sleeve cleaning without disassembly or operational interruption.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Germicidal Lamp Details<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The germicidal lamps emit approximately 95% of their UV energy at 254 nanometers, a wavelength that is highly effective at destroying bacteria, mold, and viruses. Here are the specifics for the S2400C:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Model<\/strong>: S2400C<\/li>\n\n\n\n<li><strong>Lamp Code<\/strong>: 05-1311-R<\/li>\n\n\n\n<li><strong>Lamp Length<\/strong>: 46 1\/4&#8243; (1175mm)<\/li>\n\n\n\n<li><strong>Power Consumption<\/strong>: 110 Watts<\/li>\n\n\n\n<li><strong>UV Output<\/strong>: 48.0 Watts<\/li>\n\n\n\n<li><strong>Rated Effective Life<\/strong>: 10,000 Hours<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caution<\/strong>: Direct or reflected exposure to germicidal UV rays can cause eye irritation and skin reddening. Suitable face shields, gloves, and protective clothing are recommended for those who might be exposed.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Applications<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The Sanitron UV Water Purification Systems are versatile and suitable for a variety of applications, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Institutional<\/strong>: Laboratories, hospitals, schools, and veterinary clinics.<\/li>\n\n\n\n<li><strong>Community<\/strong>: Apartment complexes, villages, and rural water systems.<\/li>\n\n\n\n<li><strong>Industry<\/strong>: Pharmaceutical manufacturing, food industry, and cooling towers.<\/li>\n\n\n\n<li><strong>Specialized Uses<\/strong>: TOC and ozone reduction, water vending machines, and aquariums.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Why Choose UV Purification?<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">UV purification is an efficient, environmentally friendly way to ensure safe drinking water. Unlike chemical methods, UV treatment does not alter the taste or odor of water, and there\u2019s no risk of chemical overdosing. It\u2019s a rapid and effective solution for destroying harmful microorganisms.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about UV light as a cleaning solution and its interaction with ozone, <a href=\"#\">click here<\/a>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Additional Models<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Sanitron offers a range of UV systems to meet various needs:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Model<\/th><th>Voltage<\/th><th>GPM<\/th><th>Inlet\/Outlet<\/th><th>Power Usage<\/th><th>Height<\/th><th>Length<\/th><th>Width<\/th><\/tr><\/thead><tbody><tr><td>S17A<\/td><td>120<\/td><td>3<\/td><td>3\/4&#8243; NPT<\/td><td>18W<\/td><td>8.1875&#8243;<\/td><td>19.375&#8243;<\/td><td>4.3125&#8243;<\/td><\/tr><tr><td>S23C<\/td><td>120<\/td><td>6<\/td><td>3\/4&#8243;NPT<\/td><td>25W<\/td><td>8.1875&#8243;<\/td><td>25.375&#8243;<\/td><td>4.3125&#8243;<\/td><\/tr><tr><td>S37C<\/td><td>120<\/td><td>12<\/td><td>1&#8243;NPT<\/td><td>48W<\/td><td>9.5&#8243;<\/td><td>39.375&#8243;<\/td><td>5.6875&#8243;<\/td><\/tr><tr><td>S50C<\/td><td>120<\/td><td>20<\/td><td>1-1\/2&#8243; NPT<\/td><td>65W<\/td><td>9.5&#8243;<\/td><td>52.375&#8243;<\/td><td>5.6875&#8243;<\/td><\/tr><tr><td>S2400C<\/td><td>120<\/td><td>40<\/td><td>2&#8243; NPT<\/td><td>140W<\/td><td>11.125&#8243;<\/td><td>52.375&#8243;<\/td><td>6.625&#8243;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\"><\/h4>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">Embrace a chemical-free, efficient water purification solution with the Sanitron S2400C. Your health and safety are just a click away!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview The Sanitron S2400C Ultraviolet Water Purification System is a state-of-the-art solution for ensuring clean, safe water. Utilizing germicidal ultraviolet (UV) lamps, this system purifies [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":4656,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"aside","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[211],"tags":[],"class_list":["post-4655","post","type-post","status-publish","format-aside","has-post-thumbnail","hentry","category-ozone-industry-news","post_format-post-format-aside"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4655","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=4655"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4655\/revisions"}],"predecessor-version":[{"id":4657,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/4655\/revisions\/4657"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/4656"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=4655"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=4655"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=4655"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}