{"id":5585,"date":"2025-06-11T09:00:00","date_gmt":"2025-06-11T14:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=5585"},"modified":"2025-06-03T09:50:06","modified_gmt":"2025-06-03T14:50:06","slug":"b14-gas-alarm-module-receiver-flexible-reliable-gas-monitoring-for-any-facility","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/b14-gas-alarm-module-receiver-flexible-reliable-gas-monitoring-for-any-facility\/","title":{"rendered":"B14 Gas Alarm Module Receiver: Flexible, Reliable Gas Monitoring for Any Facility"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">If you&#8217;re tasked with monitoring gas levels across multiple rooms or remote locations, the <strong>B14 Gas Alarm Module Receiver<\/strong> is your ideal solution. Designed to interface with industry-standard 4-20mA gas transmitters, the B14 offers a powerful, customizable platform for centralized gas monitoring\u2014even when sensors are located up to <strong>10,000 feet away<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you&#8217;re working with transmitters that include a built-in display or not, the B14 ensures reliable, real-time visibility of gas levels from a safe, centralized point. Compatible with <strong>38 different gases<\/strong>, this system provides unmatched flexibility for labs, manufacturing plants, water treatment facilities, and more.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>What Makes the B14 Stand Out?<\/strong><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Centralized Display for Distributed Sensors<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The B14 accepts signals from two, three, or four-wire 4-20mA transmitters\u2014no matter the manufacturer. Whether you&#8217;re monitoring CO\u2082, ammonia, chlorine, hydrogen sulfide, or any other hazardous gas, the B14 can consolidate that data to a single, easy-to-read <strong>LED display<\/strong> showing concentrations in <strong>PPM, PPB, % Volume, or %LEL<\/strong>, depending on your specified configuration.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Key Features at a Glance<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>LED Display:<\/strong> Displays real-time gas concentration levels in the measurement unit of your choice.<\/li>\n\n\n\n<li><strong>Three Configurable Alarm Setpoints:<\/strong> With visual indicators (flashing and steady LEDs), you can monitor caution, warning, and critical thresholds.<\/li>\n\n\n\n<li><strong>Three Relay Outputs per Module:<\/strong> Assign relays to any alarm point and configure as latching, non-latching, fail-safe, or standard.<\/li>\n\n\n\n<li><strong>Trouble Alarm &amp; Relay:<\/strong> Automatically detects signal loss or low 4-20mA input and activates a dedicated trouble alarm.<\/li>\n\n\n\n<li><strong>Remote Reset:<\/strong> Acknowledge alarms remotely using an unpowered contact or telemetry interface.<\/li>\n\n\n\n<li><strong>24 VDC Transmitter Power:<\/strong> Supports both 2- and 3-wire transmitters with built-in power output.<\/li>\n\n\n\n<li><strong>Signal Retransmission:<\/strong> 4-20mA output is isolated from the input to prevent ground faults and signal interference.<\/li>\n\n\n\n<li><strong>DC-Powered (12\u201328 VDC):<\/strong> Flexible power input supports external power or optional internal supply and battery backup.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Customizable and Expandable<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">B14 systems are <strong>modular<\/strong>, allowing you to scale from a single gas detection point to a network of up to <strong>nine receivers<\/strong> in one enclosure. Based on your application and infrastructure, you can choose from the following enclosure sizes:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Enclosure Size<\/strong><\/th><th><strong>Configuration Examples<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Single Module<\/td><td>1 receiver (DC power only)<\/td><\/tr><tr><td>Two Module<\/td><td>2 receivers (user-supplied power) OR 1 receiver + 1 power supply<\/td><\/tr><tr><td>Three Module<\/td><td>3 receivers OR 2 receivers + 1 power supply<\/td><\/tr><tr><td>Six Module<\/td><td>6 receivers OR 4 receivers + 2 power supplies<\/td><\/tr><tr><td>Nine Module<\/td><td>9 receivers (DC powered) OR 8 receivers + 1 high-wattage power supply<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong> All modules are mounted inside <strong>NEMA 4X enclosures<\/strong> using a <strong>35mm DIN rail<\/strong>, ensuring a weather-resistant, secure housing for industrial environments.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Add-On Options for Enhanced Safety<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The B14 supports a variety of accessories to expand your alerting system:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Audible &amp; Visual Alarms<\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Internal Horn (12 VDC)<\/strong><\/li>\n\n\n\n<li><strong>External Horns<\/strong> (120 VAC or 220 VAC)<\/li>\n\n\n\n<li><strong>Red or Amber Strobes<\/strong> (12 VDC, 120 VAC, or 230 VAC)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Battery Backup<\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Available in a separate NEMA 4X enclosure to keep your system running during power outages.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Power Supplies<\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Receiver Alarm Module Power Supply (00-0055):<\/strong> Powers up to 3 alarm modules<\/li>\n\n\n\n<li><strong>High Capacity Power Supply (28-0004):<\/strong> Supports up to 12 alarm modules<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Custom Orders Made Easy<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Each B14 module is custom-configured based on the gases and concentration ranges <strong>you specify<\/strong>. Whether you&#8217;re monitoring ammonia at 0\u2013100 PPM or CO\u2082 at 0\u20135%, your module will be factory-calibrated and pre-configured to your specific needs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because of this customization, <strong>orders are placed directly through consultation<\/strong>. Just contact us to specify your sensors, ranges, and enclosure requirements, and we\u2019ll configure a system tailored to your exact application.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Perfect for Multi-Room or Remote Monitoring<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The B14 is ideal for any facility that needs gas monitoring in multiple zones but prefers a centralized monitoring hub. It\u2019s widely used in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Chemical processing facilities<\/li>\n\n\n\n<li>Laboratories and clean rooms<\/li>\n\n\n\n<li>Water and wastewater treatment plants<\/li>\n\n\n\n<li>Agricultural operations<\/li>\n\n\n\n<li>Food production facilities<\/li>\n\n\n\n<li>Parking garages and confined spaces<\/li>\n\n\n\n<li>Warehouses and loading docks<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Why Choose the B14?<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Unmatched Compatibility:<\/strong> Works with any 4-20mA gas sensor, regardless of brand or type<\/li>\n\n\n\n<li><strong>Extremely Customizable:<\/strong> Configurable for different gases, ranges, alarms, and outputs<\/li>\n\n\n\n<li><strong>Reliable Long-Distance Communication:<\/strong> Transmitter to receiver distance up to 10,000 feet<\/li>\n\n\n\n<li><strong>Compact and Modular Design:<\/strong> Scalable to grow with your application<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Get Started Today<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Need to monitor multiple gases across various zones from one location? The <strong>B14 Gas Alarm Module Receiver<\/strong> gives you complete visibility, alarm management, and control\u2014all in a customizable, compact design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.oxidationtech.com\/b14-alarm-system.html\" data-type=\"link\" data-id=\"https:\/\/www.oxidationtech.com\/b14-alarm-system.html\">https:\/\/www.oxidationtech.com\/b14-alarm-system.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you&#8217;re tasked with monitoring gas levels across multiple rooms or remote locations, the B14 Gas Alarm Module Receiver is your ideal solution. Designed to [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":5586,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1244],"tags":[1412,187,73],"class_list":["post-5585","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ozone-monitor","tag-fixed-mount","tag-ozone","tag-ozone-monitor"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=5585"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5585\/revisions"}],"predecessor-version":[{"id":5587,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5585\/revisions\/5587"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/5586"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=5585"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=5585"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=5585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}