{"id":5898,"date":"2025-10-06T09:00:00","date_gmt":"2025-10-06T14:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=5898"},"modified":"2025-09-29T09:05:18","modified_gmt":"2025-09-29T14:05:18","slug":"oxo8-oem-assembly-compact-oem-oxygen-concentrator-module","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/oxo8-oem-assembly-compact-oem-oxygen-concentrator-module\/","title":{"rendered":"OXO8-OEM-Assembly \u2013 Compact OEM Oxygen Concentrator Module"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The <strong>OXO8-OEM-Assembly<\/strong> is a compact, high-quality <strong>OEM oxygen concentrator module<\/strong> that integrates easily into your existing system. Requiring only <strong>compressed air and electrical power<\/strong>, the OXO8-OEM delivers reliable oxygen production in a small footprint, making it ideal for applications where space is limited and consistent oxygen purity is essential.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong> If the environment exceeds <strong>95\u00b0F<\/strong> and standing water is present nearby, additional provisions must be made to remove excess moisture from the air to protect performance and longevity.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Turnkey OEM design<\/strong> \u2013 requires only compressed air and electrical power for operation<\/li>\n\n\n\n<li><strong>Air pressure gauge<\/strong> \u2013 provides clear system monitoring<\/li>\n\n\n\n<li><strong>Built-in pressure relief valve<\/strong> \u2013 ensures safety and protects components<\/li>\n\n\n\n<li><strong>Reliable oxygen output<\/strong> \u2013 continuous, steady performance<\/li>\n\n\n\n<li><strong>Rebuildable design<\/strong> \u2013 sieve beds and valves are replaceable, extending service life<\/li>\n\n\n\n<li><strong>Low-cost long-term operation<\/strong> \u2013 affordable maintenance with readily available parts<\/li>\n\n\n\n<li><strong>Easily integrated<\/strong> \u2013 compact module fits seamlessly into larger systems<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">How It Works \u2013 Pressure Swing Adsorption (PSA)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The OXO8-OEM uses <strong>Pressure Swing Adsorption (PSA)<\/strong> technology to separate oxygen from air:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Clean, dry compressed air enters the first molecular sieve bed.<\/li>\n\n\n\n<li>The sieve adsorbs nitrogen, allowing oxygen to flow through.<\/li>\n\n\n\n<li>Once the first bed reaches nitrogen saturation, airflow is switched to the second bed.<\/li>\n\n\n\n<li>While the second bed produces oxygen, the first vents nitrogen and regenerates.<\/li>\n\n\n\n<li>The cycle repeats continuously, ensuring a <strong>consistent, reliable flow of oxygen<\/strong>.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">This proven process makes the OXO8-OEM a dependable choice for applications requiring steady oxygen generation without bulky equipment.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>OXO8-OEM-Assembly<\/strong> is ideal for OEMs and system integrators looking to add oxygen production capability to their equipment. Typical applications include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Water treatment systems<\/li>\n\n\n\n<li>Laboratory equipment<\/li>\n\n\n\n<li>Medical or industrial process support<\/li>\n\n\n\n<li>Ozone generation systems requiring high-purity oxygen feed<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>OXO8-OEM-Assembly<\/strong> offers a <strong>compact, rebuildable, and cost-effective oxygen concentrator module<\/strong> that\u2019s easy to integrate and maintain. With its PSA technology, built-in safety features, and reliable performance, it\u2019s a long-term solution for any system requiring dependable oxygen purity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you\u2019re designing or upgrading equipment and need a dependable oxygen source, the OXO8-OEM is an excellent choice.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.oxidationtech.com\/oxo8-oem-assembly.html\" data-type=\"link\" data-id=\"https:\/\/www.oxidationtech.com\/oxo8-oem-assembly.html\">https:\/\/www.oxidationtech.com\/oxo8-oem-assembly.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The OXO8-OEM-Assembly is a compact, high-quality OEM oxygen concentrator module that integrates easily into your existing system. Requiring only compressed air and electrical power, the [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":5899,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1326],"tags":[289],"class_list":["post-5898","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oxygen-concentrator-2","tag-oxygen-concentrator"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=5898"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5898\/revisions"}],"predecessor-version":[{"id":5900,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5898\/revisions\/5900"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/5899"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=5898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=5898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=5898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}