{"id":5915,"date":"2025-10-13T09:00:00","date_gmt":"2025-10-13T14:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=5915"},"modified":"2025-10-06T09:04:45","modified_gmt":"2025-10-06T14:04:45","slug":"uv-106-mh-ozone-analyzer-with-nema-enclosure","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/uv-106-mh-ozone-analyzer-with-nema-enclosure\/","title":{"rendered":"UV-106-MH Ozone Analyzer with NEMA Enclosure"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">High-Range Ozone Measurement for Industrial Process Verification<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>UV-106-MH Ozone Analyzer<\/strong> is a <strong>high-range ozone analyzer<\/strong> designed to accurately measure ozone concentrations up to <strong>20% by weight<\/strong> (or <strong>14% by volume<\/strong>) in gas streams. This model is ideal for <strong>verifying ozone generator performance<\/strong> and monitoring high-concentration ozone in industrial processes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>NEMA enclosure<\/strong> provides durable protection for the analyzer, allowing it to be <strong>mounted in rugged environments<\/strong> or <strong>placed on a shelf<\/strong> for easy access. The enclosure safeguards the instrument from dust, moisture, and debris\u2014making it suitable for demanding industrial and laboratory conditions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Reliable, High-Range Ozone Measurement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>UV-106-MH<\/strong> uses <strong>ultraviolet (UV) absorption technology<\/strong> to detect and quantify ozone. An integrated <strong>sample pump<\/strong> continuously draws a gas sample from your process into the analyzer. A <strong>UV lamp and receptor<\/strong> measure the ozone concentration based on the absorption of UV light at a specific wavelength.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This proven detection method offers <strong>exceptional accuracy and stability<\/strong>, even at extremely high ozone concentrations. The UV-106-MH is ideal for <strong>ozone generator output verification<\/strong> and process monitoring applications requiring precise, high-level ozone measurements.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Measurement Based on UV Absorption<\/strong> \u2013 Accurate and stable ozone detection technology.<\/li>\n\n\n\n<li><strong>Wide Measurement Range<\/strong> \u2013 0\u201320% by weight or 0\u201314% by volume.<\/li>\n\n\n\n<li><strong>High Resolution<\/strong> \u2013 0.01% resolution ensures precise readings.<\/li>\n\n\n\n<li><strong>Low Power Consumption<\/strong> \u2013 Operates efficiently; can be powered by battery.<\/li>\n\n\n\n<li><strong>Integrated Sample Pump<\/strong> \u2013 Continuously draws gas from the process stream for real-time analysis.<\/li>\n\n\n\n<li><strong>Internal Data Logger<\/strong> \u2013 Built-in real-time clock with data storage capabilities.<\/li>\n\n\n\n<li><strong>User-Friendly Interface<\/strong> \u2013 On-board microprocessor with interactive menus and data averaging options (10 s, 1 m, 5 m, 1 hr).<\/li>\n\n\n\n<li><strong>Versatile Output Options<\/strong> \u2013 USB and RS-232 digital outputs provide time, date, ozone concentration, temperature, and pressure data.<\/li>\n\n\n\n<li><strong>Analog Output<\/strong> \u2013 0\u20132.5 V and 4\u201320 mA outputs for ozone concentration in user-selected units.<\/li>\n\n\n\n<li><strong>Dual-Level Relay Control<\/strong> \u2013 Enables automatic control of ozone sources or warning indicators.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Standard Enclosure Options<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Bench Mount Configuration<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The standard UV-106 model is available in a <strong>bench mount configuration<\/strong>, providing easy setup for laboratory, research, and process applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>NEMA Enclosure Configuration<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>UV-106-MH with NEMA enclosure<\/strong> adds an extra layer of protection for field or industrial installations. This version is built to withstand challenging environmental conditions, allowing flexible mounting options while maintaining analyzer performance and integrity.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">OEM Version<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For system integrators and equipment manufacturers, the <strong>OEM version<\/strong> of the UV-106 provides an <strong>\u201cozone analyzer on a board\u201d<\/strong> configuration. Nearly all components are mounted directly to the printed circuit board, enabling seamless integration into custom systems or OEM equipment designs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This compact and cost-effective version delivers the same precise ozone measurement capabilities without the need for a full enclosure.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Maintenance and Filters<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To ensure accurate and reliable operation, regular maintenance of the <strong>filters<\/strong> and <strong>ozone scrubber<\/strong> is essential:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Filter Housing:<\/strong> Replace filters frequently to prevent particulate contamination in the sample flow path.<\/li>\n\n\n\n<li><strong>Ozone Scrubber:<\/strong> The internal ozone scrubber should be replaced regularly to maintain system cleanliness and measurement accuracy.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Proper filter maintenance extends the life of the analyzer and ensures continued precision in ozone measurement.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>UV-106-MH Ozone Analyzer<\/strong> is designed for <strong>industrial and research applications<\/strong> requiring accurate high-level ozone measurement, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ozone generator output verification<\/li>\n\n\n\n<li>Process control and quality assurance<\/li>\n\n\n\n<li>Ozone system calibration and testing<\/li>\n\n\n\n<li>Environmental and laboratory research<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>UV-106-MH with NEMA enclosure<\/strong> combines <strong>rugged construction<\/strong> with <strong>laboratory-grade measurement accuracy<\/strong>. Its wide detection range, integrated pump, and digital\/analog outputs make it one of the most versatile high-range ozone analyzers available today.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you need continuous process verification, ozone production measurement, or high-concentration ozone monitoring, the UV-106-MH delivers <strong>precision, durability, and reliability<\/strong>\u2014even in the most challenging environments.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.oxidationtech.com\/uv-106mh-nema.html\" data-type=\"link\" data-id=\"https:\/\/www.oxidationtech.com\/uv-106mh-nema.html\">https:\/\/www.oxidationtech.com\/uv-106mh-nema.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>High-Range Ozone Measurement for Industrial Process Verification The UV-106-MH Ozone Analyzer is a high-range ozone analyzer designed to accurately measure ozone concentrations up to 20% [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":5916,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1244],"tags":[187,73,35],"class_list":["post-5915","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ozone-monitor","tag-ozone","tag-ozone-monitor","tag-ozone-water-treatment"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5915","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=5915"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5915\/revisions"}],"predecessor-version":[{"id":5917,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/5915\/revisions\/5917"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/5916"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=5915"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=5915"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=5915"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}