{"id":6217,"date":"2025-12-31T09:00:00","date_gmt":"2025-12-31T15:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=6217"},"modified":"2025-12-09T10:02:37","modified_gmt":"2025-12-09T16:02:37","slug":"understanding-uv-absorption-technology-for-gas-measurement","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/understanding-uv-absorption-technology-for-gas-measurement\/","title":{"rendered":"Understanding UV Absorption Technology for Gas Measurement"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Reliability<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">UV absorption<\/a> technology is one of the most reliable methods for measuring gas concentrations in a wide range of applications. This approach works on a straightforward principle: gases absorb ultraviolet light at specific wavelengths. By sending UV light through a sample and measuring how much is absorbed, an analyzer can determine the exact concentration of the gas present.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Precision<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">What makes <a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">UV absorption<\/a> especially useful is its precision. It\u2019s not influenced by humidity, temperature shifts, or the presence of most other gases, which helps ensure stable and accurate readings. This durability also means the system requires less frequent maintenance than many other measurement methods.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Flexibility<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Another advantage is its flexibility. <a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">UV analyzers<\/a> can be configured for low-level or high-concentration environments, making them valuable for industries that need dependable, continuous monitoring. Because the technology is based on optical measurement rather than chemical reactions, it offers long-term reliability without consumables or frequent calibration.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter is-resized\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\"><img loading=\"lazy\" decoding=\"async\" width=\"789\" height=\"982\" src=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2025\/12\/UV_Ozone_Analyzer_operation-1.png\" alt=\"UV analyzer setup Oxidation Technologies and Gas Sensing\" class=\"wp-image-6223\" style=\"aspect-ratio:0.8034864659549799;width:486px;height:auto\" srcset=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2025\/12\/UV_Ozone_Analyzer_operation-1.png 789w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2025\/12\/UV_Ozone_Analyzer_operation-1-241x300.png 241w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2025\/12\/UV_Ozone_Analyzer_operation-1-768x956.png 768w\" sizes=\"auto, (max-width: 789px) 100vw, 789px\" \/><\/a><figcaption class=\"wp-element-caption\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">UV Analyzer <\/a> Setup for Ozone<\/figcaption><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">Oxidation Technologies<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-center\">Did you know?<\/h3>\n\n\n\n<figure class=\"wp-block-image has-custom-border\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-generation\/uv-lamp.html\"><img loading=\"lazy\" decoding=\"async\" width=\"787\" height=\"421\" src=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2025\/12\/UV_light_wavelengths.png\" alt=\"UV light wavelengths\" class=\"wp-image-6224\" style=\"border-width:5px\" title=\"ozone can be generated from UV light\" srcset=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2025\/12\/UV_light_wavelengths.png 787w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2025\/12\/UV_light_wavelengths-300x160.png 300w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2025\/12\/UV_light_wavelengths-768x411.png 768w\" sizes=\"auto, (max-width: 787px) 100vw, 787px\" \/><\/a><figcaption class=\"wp-element-caption\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-generation\/uv-lamp.html\">Ultraviolet or UV light<\/a> is light that has a higher frequency than visible light. As violet is the color of the highest frequency of visible light; <a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-generation\/uv-lamp.html\">ultraviolet light<\/a> is the term we apply to light that has frequencies higher than visible light.<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>A <a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">UV ozone analyzer<\/a> typically includes:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&nbsp;UV Light Source<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Usually, a low-pressure mercury lamp producing stable UV light at 254 nm.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&nbsp;Sample Cell (Optical Pathway)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Sample gas is drawn through this <a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-chambers.html\">chamber<\/a>, and the UV light passes through it.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&nbsp;Detector<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Measures the intensity of UV light after it passes through the sample.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&nbsp;Reference Measurement<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; A second optical path or filtered air stream provides a \u201czero ozone\u201d reference.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&nbsp;Signal Processing<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">&#8211; The analyzer computes ozone concentration based on the reduction in UV intensity caused by ozone absorption.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h4 class=\"wp-block-heading has-text-align-center has-white-color has-ast-global-color-0-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-3f7fe4ce9bcb8a9055ce4d4181e0b80b\" style=\"text-transform:capitalize\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-principles-compared.html\">Compare O3 Sensor Technologies<\/a><\/h4>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">&nbsp;&nbsp;<a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-principles-compared.html#answer1\">-UV Absorption Ozone Analyzer<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">&nbsp; &nbsp; &nbsp;<a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-principles-compared.html#answer2\">-Electrochemical Ozone Sensor<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">&nbsp; &nbsp; &nbsp;&#8211;<a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-principles-compared.html#answer3\">Heated Metal Oxide Ozone (HMOS) Sensor<\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">How It Works<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>A sample of the gas is drawn into a <a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-chambers.html\">chamber<\/a>, where a UV light source shines through it at a specific wavelength.<\/li>\n\n\n\n<li>If the target gas is present, it absorbs part of that UV light. The more gas present, the more light is absorbed.<\/li>\n\n\n\n<li>By comparing the light intensity before and after it passes through the <a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-chambers.html\">chamber<\/a>, the analyzer calculates the gas concentration using a predictable absorption relationship.<\/li>\n\n\n\n<li>For additional accuracy, the system may take a baseline measurement using a \u201czero-gas\u201d sample where the target gas has been removed.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html\">UV Analyzer<\/a> <a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html\">Products<\/a><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html#uv-low-range-ozone-analyzers\">Low Range<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html#uv-medium-range-ozone-analyzers\">Medium Range<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html#uv-high-range-ozone-analyzers\">High Range<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html#uv-oem-ozone-analyzers\">UV OEM O3 Analyzers<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html#calibration-source\">Calibration Source<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html#measure-ozone-in-water\">Measure O3 in Water<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html#rental-ozone-analyzers\">Rental O3 Analyzers<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In short, UV absorption provides a clear, stable, and efficient way to measure gas concentrations\u2014ideal for operations that depend on accuracy and consistency.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><a href=\"https:\/\/www.oxidationtech.com\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"205\" src=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2015\/11\/logo-1024x205.png\" alt=\"Oxidation Technologies logo\" class=\"wp-image-1196\" style=\"aspect-ratio:4.995836802664447;width:464px;height:auto\" srcset=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2015\/11\/logo-1024x205.png 1024w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2015\/11\/logo-300x60.png 300w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2015\/11\/logo-624x125.png 624w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2015\/11\/logo.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\">General <a href=\"https:\/\/www.oxidationtech.com\/services\/ozone-calibration.html\">Calibration <\/a>Information<\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">All Gas Sensors will require periodic <a href=\"https:\/\/www.oxidationtech.com\/services\/ozone-calibration.html\">calibration <\/a>to ensure your gas measurements are accurate and correct.&nbsp; Different gasses, and sensor manufacturers will have differing requirements and methods for <a href=\"https:\/\/www.oxidationtech.com\/services\/ozone-calibration.html\">calibration<\/a>.&nbsp; This page will serve to provide general <a href=\"https:\/\/www.oxidationtech.com\/services\/ozone-calibration.html\">calibration <\/a>information and links to specific <a href=\"https:\/\/www.oxidationtech.com\/services\/ozone-calibration.html\">calibration <\/a>procedures from the sensor manufacturers we represent.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Should you have any questions about sensor <a href=\"https:\/\/www.oxidationtech.com\/services\/ozone-calibration.html\">calibration<\/a>, or would like us to help you with your <a href=\"https:\/\/www.oxidationtech.com\/services\/ozone-calibration.html\">calibrations&nbsp;<\/a>please <a href=\"https:\/\/www.oxidationtech.com\/contact\/\">contact us.<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Reliability UV absorption technology is one of the most reliable methods for measuring gas concentrations in a wide range of applications. This approach works on [&hellip;]<\/p>\n","protected":false},"author":19,"featured_media":6219,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1457,2,1473,211,1462,1372],"tags":[1186,1478,284,1479,1469,998,1477,507],"class_list":["post-6217","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-calibration","category-gas-sensing-news","category-oxidation-technologies","category-ozone-industry-news","category-uv-absorption-ozone-analyzer","category-uv-lights","tag-calibration","tag-gas-measurement","tag-oxidation-technologies","tag-ozone-creation","tag-uv-absorption-ozone-analyzer","tag-uv-lamp","tag-uv-light","tag-uv-light-ozone-production"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/6217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=6217"}],"version-history":[{"count":5,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/6217\/revisions"}],"predecessor-version":[{"id":6226,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/6217\/revisions\/6226"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/6219"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=6217"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=6217"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=6217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}