{"id":6902,"date":"2026-10-28T09:00:00","date_gmt":"2026-10-28T14:00:00","guid":{"rendered":"https:\/\/www.oxidationtech.com\/blog\/?p=6902"},"modified":"2026-09-09T09:46:58","modified_gmt":"2026-09-09T14:46:58","slug":"rebuild-kit-for-our-cdu-ozone-destruct-unit","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/rebuild-kit-for-our-cdu-ozone-destruct-unit\/","title":{"rendered":"Rebuild kit for our CDU Ozone Destruct Unit:"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">As your destruct unit ages the catalyst material will become contaminated with dust, hydrocarbons, NOx, and other potential contaminates.&nbsp; This will cause lower ozone destruction efficiency over time.&nbsp; We suggest replacing the catalyst material annually in critical applications to ensure continuous and reliable ozone destruction.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Rebuild kits include:<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Sufficient catalyst material <a href=\"https:\/\/www.oxidationtech.com\/carulite-200.html\">(Carulite 200)<\/a> to replace all the catalyst in your CDU destruct unit 1 time<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Replacement screens for the cap of the CDU destruct unit<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Everything required for catalyst replacement is included.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.34%\">\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/www.oxidationtech.com\/products\/accessories\/ozone-destruct.html#:~:text=Destruct%20Unit%20Replacement%20Parts\"><img decoding=\"async\" src=\"https:\/\/www.oxidationtech.com\/media\/catalog\/product\/cache\/74c1057f7991b4edb2bc7bdaa94de933\/i\/m\/img_5098_edited.png\" alt=\"CDU-300 Rebuild Kit\" style=\"width:158px;height:auto\" title=\"CDU-300 Rebuild Kit\" \/><\/a><figcaption class=\"wp-element-caption\">Destruct Unit Replacement Parts<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/www.oxidationtech.com\/products\/accessories\/ozone-destruct.html#:~:text=Destruct%20Unit%20Replacement%20Parts\"><img decoding=\"async\" src=\"https:\/\/www.oxidationtech.com\/media\/catalog\/product\/cache\/74c1057f7991b4edb2bc7bdaa94de933\/i\/m\/img_9974.png\" alt=\"CDU-30 Rebuild Kit\" style=\"aspect-ratio:1;width:172px;height:auto\" title=\"CDU-30 Rebuild Kit\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.34%\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.oxidationtech.com\/carulite-200.html\"><img decoding=\"async\" src=\"https:\/\/www.oxidationtech.com\/media\/catalog\/product\/cache\/74c1057f7991b4edb2bc7bdaa94de933\/3\/_\/3.carulite.png\" alt=\"Bucket of Carulite-200\" style=\"aspect-ratio:1\" title=\"Bucket of Carulite-200\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>FAQ:<\/strong><\/h2>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>How long does the catalyst last?<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Catalyst life will be dependent upon contaminates and overall use. We recommend replacing catalyst annually to ensure continuous and reliable ozone destruction.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>What shortens the catalyst life?<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Water condensing on the catalyst will damage the catalyst that water condenses on. This is why heaters and water traps are recommended on all applications where ozone is destroyed in moist air or ozone off-gas applications<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Hydrocarbons, VOC\u2019s, Sulfer compounds, Halogenated compounds, Heavy metals, Nox, and Silica will all poison the catalyst and shorten the life.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Is there a shelf life for the catalyst? Can we buy a rebuild kit and keep it on the shelf?<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; There is no shelf life for the catalyst. It will last indefinitely on the shelf. Store in cool, dry area in a closed container. Segregate from easy oxidizable materials.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Is the spent catalyst considered a hazardous material?<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; The catalyst is not a hazardous substance, however it should be handled with care. Protective equipment in handling including, safety glasses, and gloves should be used.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Disposal of the catalyst in a standard landfill is approved after verifying that it is not contaminated with hazardous substances through usage.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Do you offer repair\/rebuild kits for other brands of destruct units?<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">&#8211; Yes we do. The <a href=\"https:\/\/www.oxidationtech.com\/carulite-200.html\">Carulite 200 <\/a>material used for catalyst material is the same in most all catalytic ozone destruct units. We can provide this catalyst, screens, gaskets, heaters, water traps and every part you might need.\u00a0<a href=\"https:\/\/www.oxidationtech.com\/contact-us.html\">Contact us for details.<\/a><\/p>\n\n\n<div class=\"wp-block-site-logo\"><a href=\"https:\/\/www.oxidationtech.com\/blog\/\" class=\"custom-logo-link\" rel=\"home\"><img loading=\"lazy\" decoding=\"async\" width=\"369\" height=\"78\" src=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2018\/11\/oxidationtech-logo-330x70.png\" class=\"custom-logo\" alt=\"oxidationtech-logo\" srcset=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2018\/11\/oxidationtech-logo.png 1125w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2018\/11\/oxidationtech-logo-300x64.png 300w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2018\/11\/oxidationtech-logo-1024x218.png 1024w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2018\/11\/oxidationtech-logo-768x164.png 768w, https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2018\/11\/oxidationtech-logo-330x70.png 330w\" sizes=\"auto, (max-width: 369px) 100vw, 369px\" \/><\/a><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>As your destruct unit ages the catalyst material will become contaminated with dust, hydrocarbons, NOx, and other potential contaminates.&nbsp; This will cause lower ozone destruction [&hellip;]<\/p>\n","protected":false},"author":19,"featured_media":6903,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1211,211,1293,1786,1461],"tags":[2033,2028,2032,2031,2036,1238,284,884,2035,2029,2030,2034,992],"class_list":["post-6902","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ozone-destruct-unit","category-ozone-industry-news","category-replacement-parts","category-safety","category-service-and-repair","tag-blower-unit","tag-catalyst","tag-cdu","tag-cdu-ozone-destruct-unit","tag-destruct-repair-kit","tag-destruct-unit","tag-oxidation-technologies","tag-ozone-destruct","tag-ozone-destruct-unit-replacement-parts","tag-ozone-destruction","tag-rebbuild-kit","tag-rebuild","tag-safety"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/6902","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=6902"}],"version-history":[{"count":1,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/6902\/revisions"}],"predecessor-version":[{"id":6904,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/6902\/revisions\/6904"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media\/6903"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=6902"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=6902"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=6902"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}