{"id":856,"date":"2015-03-31T02:25:16","date_gmt":"2015-03-31T02:25:16","guid":{"rendered":"http:\/\/ozone-services.com\/?p=856"},"modified":"2015-03-31T02:25:16","modified_gmt":"2015-03-31T02:25:16","slug":"ati-sensor-calibration","status":"publish","type":"post","link":"https:\/\/www.oxidationtech.com\/blog\/ati-sensor-calibration\/","title":{"rendered":"ATI SENSOR CALIBRATION"},"content":{"rendered":"<h1>ANALYTICAL TECHNOLOGIES INCORPORATED (ATI)<\/h1>\n<p><strong><em>This information applies to the sensor module used in the<span class=\"Apple-converted-space\">\u00a0<\/span><a title=\"C16 Porta sens\" href=\"https:\/\/www.gas-sensing.com\/ati-products\/c-16-gas-detector.html\" target=\"_self\">C16<\/a>,<span class=\"Apple-converted-space\">\u00a0<\/span><a title=\"F12 Gase transmitter\" href=\"https:\/\/www.gas-sensing.com\/ati-products\/f-12-gas-transmitter.html\" target=\"_self\">F12<\/a>, and<span class=\"Apple-converted-space\">\u00a0<\/span><a title=\"D12 gas sensor\" href=\"https:\/\/www.gas-sensing.com\/ati-products\/d-12-toxic-gas-transmitter.html\" target=\"_self\">D12<\/a><span class=\"Apple-converted-space\">\u00a0<\/span>Monitors.<\/em><\/strong><\/p>\n<p>ATI Smart Sensors come pre-calibrated and have all calibration information loaded on the sensor.\u00a0 The sensor can be swapped between monitors without any special requirements for proper calibration.<\/p>\n<p>Sensors are fairly low cost and are replaced annually to remain in calibration.\u00a0 Periodic bump tests can be performed to ensure the sensor is still operating, but no calibration is typically necessary.<\/p>\n<p><a title=\"ATI products\" href=\"https:\/\/www.gas-sensing.com\/ati-products.html\" target=\"_self\"><em><strong>ATI Product List<\/strong><\/em><\/a><\/p>\n<p><strong>\u00a0Calibration Frequency<\/strong><\/p>\n<p>While the transmitter itself requires no periodic calibration, H10 sensors should be \u201czero\u201d and \u201cspan\u201d calibrated every 3-6 months, based upon environmental factors. Sensors frequently exposed to dirt, oil mist, vapors, or very dry air, may require more frequent calibration.<\/p>\n<p><strong>Zero Calibration<\/strong><\/p>\n<p>As the name implies, zero calibration corrects the transmitter reading to zero in the absence of any reactive gas. During zero calibration, the transmitter offset error is stored, and subsequently subtracted from future readings. ATI recommends bottled zero gas as a source, which should be selected based on the type of sensor. For example, bottled \u201cZero\u201d Air may be used to zero Chlorine sensors, but Oxygen sensors require bottled Nitrogen gas.<\/p>\n<p><strong>Span Calibration<\/strong><\/p>\n<p>The role of span calibration is to correct the transmitter reading to a known concentration of target gas (the gas for which the sensor was designed to monitor). During span calibration, the transmitter effectively stores the slope of the error, and divides it out of subsequent readings. Sensors for most gases, such as Ammonia, require a bottled \u201cspan gas\u201d source. This applies even to Oxygen sensors, where the span gas source is bottled zero air.<\/p>\n<p><strong>Calibration Terminology<\/strong><\/p>\n<p>The zero calibration is referred to as, \u201czero\u201d, \u201czeroing\u201d, and \u201czeroed\u201d. Likewise for the span calibration, which appears as, \u201cspan\u201d, \u201cspanning\u201d, and \u201cspanned\u201d. As with most instruments, zero calibration should be performed before span.<\/p>\n<p><strong>Calibration Kits<\/strong><\/p>\n<p>Calibration kits, containing zero and span bottle gas sources, are available from ATI for many toxic gases.<span class=\"Apple-converted-space\">\u00a0<\/span><a title=\"Contact gas sensing\" href=\"https:\/\/www.gas-sensing.com\/contact-us\" target=\"_self\">Contact Gas Sensing<\/a>, if you have questions about calibration gas kits or gas sources.<\/p>\n<p>ATI does provide a special kit for ozone gas calibration as ozone cannot be supplied in a calibration gas cylinder.\u00a0 The<span class=\"Apple-converted-space\">\u00a0<\/span><a title=\"A23-14 Ozone Gas CAlibrator Product Specifications\" href=\"https:\/\/www.gas-sensing.com\/accessories\/a23-14-calibrator.html\" target=\"_blank\">A23-14 can be used for all ATI ozone products<\/a><span class=\"Apple-converted-space\">\u00a0<\/span>along with other ozone sensors.\u00a0<a title=\"A23-14 Ozone Gas CAlibrator Product Specifications\" href=\"https:\/\/www.gas-sensing.com\/contact-us\" target=\"_blank\">Contact gas sensing for details.<\/a><\/p>\n<p><a title=\"A23-14 Ozone Calibration Kit\" href=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\" target=\"_self\"><img decoding=\"async\" src=\"https:\/\/www.gas-sensing.com\/media\/catalog\/product\/cache\/1\/thumbnail\/75x\/9df78eab33525d08d6e5fb8d27136e95\/a\/2\/a23-14.png\" alt=\"A23-14 Ozone Calibration Kit\" \/><\/a><\/p>\n<p><strong>Indications During Sensor Calibration<\/strong><\/p>\n<p>The \u201cun-blanked\u201d gas concentration value is displayed during zero and span calibration, primarily to observe any slight amount of positive or negative drift. In addition, alarms are cleared and inhibited, and the 4-20mA output of the F12 transmitter is locked at 4.0mA (transmitters equipped with Oxygen sensors are locked at 17.4mA, representing normal, 20.9% atmospheric Oxygen). The 4-20mA output will not change when gas is applied and removed, and for 15 minutes thereafter (the default value). While viewing the calibration pages, the LCD display will indicate the changing gas concentration.<\/p>\n<p><strong>Calibration Exceptions<\/strong><\/p>\n<p>Zero and span calibration are not allowed during the following conditions: v Sensor removed, or in 5-minute8 warm-up period v Transmitter fault is active v Auto-test is active (\u201cA\u201d status indicator appears on Main Display page) To help prevent errors, zero and span are not allowed if the sensor output, or span value entered, is too high or too low. Memory errors are reported if detected while updating the sensor or transmitter memory.<\/p>\n<p><strong>Zero Calibration Procedure<\/strong><\/p>\n<p>Performing a zero calibration requires bottled \u201cZero-gas\u201d with a 500 cc\/min regulator, calibration adapter, and a convenient length of \u00bc\u201d tubing. The gas used depends on the type of sensor installed. For example, an H2S sensor may be zeroed with Zero-air, while Oxygen sensors must be zeroed with Nitrogen. In some cases, a sensor may be zeroed directly to the atmosphere, but only when it is known to be free of reactive gasses. Check with the factory if you are uncertain about which gas to use.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"F12 zero gas calibration procedure\" src=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/D12_calibration.png\" alt=\"ATI zero gas calibration diagram\" width=\"225\" height=\"265\" \/><\/p>\n<p><strong>Span Calibration Procedure<\/strong><\/p>\n<p>Span calibration* requires bottled \u201cspan-gas\u201d with a 500 cc\/min regulator, calibration adapter, and a convenient length of \u00bc\u201d tubing. The gas type and concentration used depends on the type of sensor installed. Check with the factory if you are uncertain about which gas to use.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"Calibrate ATI D12 sensor with span gas\" src=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/D12_calibration_-_span.png\" alt=\"ATI span gas ccalibration image\" width=\"227\" height=\"246\" \/><\/p>\n<p><strong>\u00a0Sensor Calibration Records<\/strong><\/p>\n<p>A calibration record is written into the sensor memory each time a zero or span calibration is performed, and when a calibration Undo is performed. Enough memory is reserved for 63 zero calibrations and 63 span calibrations. Zero and span calibration records are accessed on the Cal_History page.<\/p>\n<p><strong>Auto-test<\/strong><\/p>\n<p>The Auto-test option verifies the serviceability of the transmitter on a prescribed schedule by exposing the sensor to a small amount of gas, and verifying a minimum response. Three attempts per test are made, and if the sensor does not respond on the third attempt, a fault alarm is triggered (may be optionally disabled). A summary of pass, fail, and retry counts are maintained in the sensor memory, and may be viewed on the Auto-test History page.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/F-12_sensor.png\" alt=\"ATI auto test generator\" width=\"278\" height=\"222\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"showing how auto-test generator attaches to F12\" src=\"https:\/\/www.gas-sensing.com\/media\/wysiwyg\/F-12_with_auto_test.png\" alt=\"F12 with auto-test generator option\" width=\"274\" height=\"408\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>The auto-test generator plugs into the bottom of the sensor holder and is connected to the monirot base.\u00a0 On a timed sequence the Auto-Test generator will test the sensor response to verify that the sensor will still respond to the necessary gas properly.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ANALYTICAL TECHNOLOGIES INCORPORATED (ATI) This information applies to the sensor module used in the\u00a0C16,\u00a0F12, and\u00a0D12\u00a0Monitors. ATI Smart Sensors come pre-calibrated and have all calibration information [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[3],"tags":[207,208,209,206,210],"class_list":["post-856","post","type-post","status-publish","format-standard","hentry","category-tech-tips","tag-ammonia-sensor-calibration","tag-detector-calibration","tag-gas-sensor-calibration","tag-ozone-sensor-calibration","tag-sensor-calibration"],"_links":{"self":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/comments?post=856"}],"version-history":[{"count":0,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/posts\/856\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/media?parent=856"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/categories?post=856"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oxidationtech.com\/blog\/wp-json\/wp\/v2\/tags?post=856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}