W1+480L Ozone Analyzer

The Model W1, combined with a Model 480L Ozone Monitor, continuously measures dissolved ozone concentrations in the liquid phase. It uses the stripping column method with advanced electronics design to deliver highly accurate and stable readings of dissolved ozone. This dissolved ozone analyzer is typically used in measuring dissolved ozone in drinking water, wastewater and DI water applications in a wide range of industries.​
120 Day Lead Time per the Manufacturer
SKU
W1+480L

Description / W1+480L Ozone Analyzer

The Model W1, combined with a Model 480L Ozone Monitor, continuously measures dissolved ozone concentrations in the liquid phase. It uses the stripping column method with advanced electronics design to deliver highly accurate and stable readings of dissolved ozone. This dissolved ozone analyzer is typically used in measuring dissolved ozone in drinking water, wastewater and DI water applications in a wide range of industries.​

Features:

- Stripping Column

- UV Absorption technique

- Highly stable optical system

- Microprocessor-based technology

- Dual field programmable alarms

- No consumables

- Reliable, repeatable and accurate​

- Graphical user interface

- LED UV lamp

- Ethernet standard

 

Specifications:

 
Measuring Principle: Transfer Method (transfer ozone from liquid to gas)
followed by absolute determination​ by UV absorption
Measuring Range: 0-1, 0-2 mg/L
Resolution: 0.001 mg/L​
Zero Drift: 0.001 mg/L per month​
Standard Alarms: Two field programmable alarms with Form C relay contacts (SPDT 5A, 250VAC resistive)
Diagnostic Features: Continuous internal diagnostics with error messages and
instrument error signal output​
Analog Outputs: 4-20 mA or 0-5 VDC standard
Communication Interface: RS-232, RS-485, MODBUS, Ethernet​
Supply Voltage: 100-240 VAC 50/60 Hz, 74W
Water Flow Rate: 1.0 LPM (Gravity fed)
Gas Flow Rate: 0.8 LPM
Connections: 1/4" compression fittings (gas)
1/4" compression or 3/8" barb (water)
Configuration: NEMA 4X IP65 Wall Mount
Dimensions (HxWxD): M480 Ozone Monitor (NEMA):
16.17” x 15.96” x 6.80“
(410.6 mm x 405.4 mm x 172.7 mm)​
Transfer Column:
39.0" x 15.0" x 4.0"
(991 mm x 381 mm x 102 mm)​
Operating Conditions: 5-45°C, 0-95% RH non-condensing
Approvals: CE​
Warranty: 1 year

 

Downloads: 

W1 Manual

480L Manual

More Information

Manufacturer Teledyne API
4-20 mA Output Yes
Maximum Range 0-2 mg/L
Minimum Range 0-1 mg/L
Accuracy 0.001 mg/L​
Min, Max, Avg No
Voltage Output 0-5 V
Power Requirements 100-240 VAC 50/60 Hz, 74W
Datalogging Yes
Rechargeable No
Warranty 1 Year
Audible Alarm Yes
Calibration Annually
Range 0-1, 0-2 mg/L
Unit Features

-Dual field programmable alarms

-Quick Response Times

-UV Absorption Methods

-Minimal Zero Drift

-Reliable, repeatable and accurate​

Sensor Range

0-1, 0-2 mg/L

Resolution 0.001 ppm
Sensor Range 0-1, 0-2 mg/L

We found other products you might like!

Navigating through the elements of the carousel is possible using the tab key. You can skip the carousel or go straight to carousel navigation using the skip links.
M465L Nema
$8,400.00
API M465M Nema 4x
$9,750.00
UV-106-L Ozone Analyzer
$5,760.00
UV-106-M Ozone Analyzer
$5,760.00
UV-106-MH Ozone Analyzer
$6,336.00
UV-106-H Ozone Analyzer
$6,336.00