OXO8 Module + Timing Board

OXO8 Module is the sieve beds, and solenoid valves installed on it for oxygen production. Requires timer board for operation of the valves. Provides 8 LPM (16.88 SCFH) oxygen at up to 15 PSI of pressure from 4 CFM compressed air. Choose your timing board
Grouped product items
Image Product Name Qty
OXO8 Module
OXO8 Module
$692.35
OXO Timing Board
OXO Timing Board
$205.20
OXO Timing Board O2 purity
OXO Timing Board O2 purity
$240.00

The OXO8 Oxygen Concentrator Module is the sieve beds and valves used on the OXO8 OEM oxygen concentrator assembly. The compact size and configurable assembly make this a great OEM oxygen concentrator option to package into your system.  This unit is an OEM component to be used with the timer board or timer board with O2 purity module.

OXO Timing Board

A wiring harness for the solenoid valves is included with the timing board.  Board requires either 120 or 220 VAC electrical power for operation, 50/60 Hz.

This is the basic timing board; this board only has the timing cycle, and no built-in analyzers/sensors. The one advantage to this board is it’s universal voltage, so it’s eliminated the need for selector shunts to set the incoming voltage. This also helps prevent any short-circuiting of board components and allows for the boards to be pulled & shipped quickly. To work, the board just needs to be connected to an incoming power supply.

OXO Timing Board O2 purity

The concentrator will never shut itself down due to purity or pressure issues. The only 3 ways of actually turning off the machine are by flipping the power switch, unplugging/disconnecting either the power cord or wiring harness from a terminal, or if the circuit breaker/thermal switch on the compressor were to trip. Outside of that, the unit will remain on, but will produce a loud audible alarm to notify the end-user of the issue. I do not know if I covered it in the past, but the LED lights on the 8400-1304 board correspond to the performance of the concentrator:

Flashing Green LED (Top LED) – Denotes that the machine is on & currently is building up its purity for use.

Solid Green LED – This will illuminate once the unit has reached at least 87% purity, and is good to begin using.

Flashing Yellow LED (Bottom LED; Alarm Function) – This indicates there’s a pressure issue; our circuit board’s pressure sensor has an operating range of 4.0 – 29.0 PSI. Should the pressure dip above or below that mark, this LED light will turn on & an alarm will let you know. Generally this means there’s either a leak somewhere, or something isn’t connected (like tubing).

Solid Yellow LED (Bottom LED; Alarm Function) – This light is designated to the oxygen purity of the system, and will turn solid yellow if the oxygen purity has dropped below 87%. This one has numerous causes, but can be usually traced back to either a low output compressor, a leak/disconnection, or an issue with the sieve bed itself.

 

Features:

     -Reliable Oxygen Production

     -Compact size

     -Rebuildable design with replaceable sieve beds and valves 

     -Low-cost long-term operation due to replaceable parts

     -Easily Integrated

 

Product Characteristics:

Input Air Requirements:

Flow

Pressure

 

4 SCFM

30 PSI 

Performance Data:

Product Flow

Oxygen Delivery Pressure

 

8 LPM (16.88 SCFH)

up to 15 PSI

Product Concentration 90-95%
Product Dew Point -100°F (-73°C)
Dimensions (DxH)

6" wide x 4" deep x 18" tall

Weight 8 lbs 

Physical Connections

Compressed Air Inlet

Product Gas Outlet

 

3/8" OD tubing

1/4" OD tubing

Ambient Operating Conditions 

Locate the oxygen concentrator system in a well-ventilated area that is protected from weather elements.

Inside room or enclosure: Temps should remain between 40°F (4°C) and 130°F (54°C) 

In storage: Temps should remain between 0°F (-18°C) and 140°F (60°C)

Control Power Requirements (Single Phase) Requires separate timer board for operation
Compressed Air Input Requirements Clean Air (oil-less). Max Temp of 170°F (77°C). Performance Rated at 120°F (49°C).
  •  

What is Pressure Swing Adsorption (PSA)

Clean, dry compressed air is fed into the first molecular sieve bed.  Nitrogen is adsorbed, while oxygen is allowed to flow through.  When the sieve in the first bed becomes full of nitrogen, the airflow is then directed into the second bed.  As the second bed separates the oxygen from the nitrogen, the first bed vents its nitrogen into the atmosphere.  Compressed air is once again fed into the first bed, and the process is repeated continuously.  A constant flow of oxygen is reliably produced.

PSA oxygen generator description

 

More Information
Call For Price No
Product Category Oxygen Generator
Lead Time In Stock
Warranty 1 Year
Country of Origin USA
Write Your Own Review
You're reviewing:OXO8 Module + Timing Board