OXO10 Module
OXO10 Module is the sieve beds, and solenoid valves installed on it for oxygen production. Requires timer board for operation of the valves.
Provides 10 LPM (21 SCFH) oxygen at up to 15 PSI of pressure from 4 CFM compressed air.
- SKU
- OXO10 Module
Description / OXO10 Module
The OXO10 Oxygen Concentrator Module is the sieve beds and valves used on the OXO10 OEM oxygen concentrator assembly. This unit can be used as a replacement component for the OXO10 OEM assembly or can be purchased as an OEM component to be used with the timer board or timer board with O2 purity (sold separate) module.
When used as an OEM oxygen concentrator the compact size and configurable assembly make this a great option to package into your system
Features:
-Reliable Oxygen Production
-Compact size
-Rebuildable design with replaceable sieve beds and valves
-Low-cost long-term operation due to replaceable parts
-Easily Integrated
Product Characteristics:
Input Air Requirements: Flow Pressure |
4 SCFM 30 PSI |
Performance Data: Product Flow Oxygen Delivery Pressure |
10 LPM (21 SCFH) up to 15 PSI |
Product Concentration | 90-95% |
Product Dew Point | -100°F (-73°C) |
Dimensions (DxH) |
6" wide x 4" deep x 20" tall |
Weight | 8 lbs |
Physical Connections Compressed Air Inlet Product Gas Outlet |
3/8" OD tubing 1/4" OD tubing |
Ambient Operating Conditions |
Locate the oxygen concentrator system in a well-ventilated area that is protected from weather elements. Inside room or enclosure: Temps should remain between 40°F (4°C) and 130°F (54°C) In storage: Temps should remain between 0°F (-18°C) and 140°F (60°C) |
Control Power Requirements (Single Phase) | Requires separate timer board for operation |
Compressed Air Input Requirements | Clean Air (oil-less). Max Temp of 170°F (77°C). Performance Rated at 120°F (49°C). |
What is Pressure Swing Adsorption (PSA):
Clean, dry compressed air is fed into the first molecular sieve bed. Nitrogen is adsorbed, while oxygen is allowed to flow through. When the sieve in the first bed becomes full of nitrogen, the airflow is then directed into the second bed. As the second bed separates the oxygen from the nitrogen, the first bed vents its nitrogen into the atmosphere. Compressed air is once again fed into the first bed, and the process is repeated continuously. A constant flow of oxygen is reliably produced.
More Information
Quickbooks Stock Level | 7.000000 |
---|---|
Quickbooks Stock Date Expected | 2024-10-17 00:00:00 |
Product Category | Oxygen Generator |
Nominal Gas Flow Rate | 21 SCFH (10 LPM) |
Features | OXO10 Module, featuring sieve beds and solenoid valves, produces 10 LPM (21 SCFH) oxygen at up to 15 PSI from 4 CFM compressed air, requiring a timer board for valve operation. |
Manufacturer | Misc |
Lead Time | In Stock |
Warranty | 1 Year |
Country of Origin | USA |