Aeroqual Nitrogen Dioxide (NO2) Sensor Head 0-1 ppm (END)

This NEW Nitrogen Dioxide (N02) Sensor Head uses Gas Sensitive Electrochemical (GSE) technology to detect Nitrogen Dioxide from 0-1 ppm with 0.001 ppm resolution and accuracy up to ±0.02 ppm.
Orders for more than 7 units will take longer to ship.
- SKU
- AQ END
Description / Aeroqual Nitrogen Dioxide (NO2) Sensor Head 0-1 ppm (END)
This the new and improved Nitrogen Dioxide (N02) Sensor Head uses Gas Sensitive Electrochemical (GSE) technology to detect Nitrogen Dioxide from 0-1 ppm with 0.001 ppm resolution and <±0.02 ppm accuracy (in concentrations from 0 - 0.2 ppm) or <± 10% accuracy (in concentrations from 0.2 -1 ppm).
This sensor uses an active sensor technology with an internal fan to pull air across the GSE sensor at a specific flow rate for accurate gas detection. This fan pulls a stream of air past the sensor every 60 seconds providing a new reading of NO2 levels and resulting in a 30 second response time. The previous versions of the NO2 sensor head used a less-specific electrochemical sensor that was cross-reactive to atmospheric ozone. This created difficulties in obtaining accurate measurements and customers would often need to use a second handheld monitor to simultaneously measure ozone. The release of this NO2 sensor head that uses a sensor with an O3 filtering layer greatly improves usability.
Full list of technical information and specifications for all Aeroqual sensors
This sensor head will be a direct fit onto any Series-200, Series-300, Series-500 or Ranger Aeroqual ozone monitor. This head can be purchased as an addition to your existing monitor, or with a new base unit. To purchase with a base unit see our Aeroqual ozone monitor page. If you currently have an Aeroqual monitor this sensor will be a direct fit for your current monitor.
Detailed Sensor Specifications for Aeroqual ambient sensors
Click on image to expand
Sensor Type:
There are two types of Aeroqual sensors, type 1 and type 2.
The type 1 is used with the S-200, S-300, S-500, Ranger and S-900 monitors.
The type 2 is calibrated specifically with fittings on the end allowing it to be used with the ENC enclosure and in the S930
All sensors require a yearly calibration to ensure your gas measurements are accurate and performing within manufacturer standards. This page is desiccated to the individual manufacturers we represent and their specific calibration procedures.
**Calibration Service Request Form **
Calibration costs do vary, see below to get an estimate: Calibration Fee: $150 Analyzer Calibration Fee: $300 PM Calibration Sensor Fee: $330 Genie Calibration Fee: $265 ATI Calibration Fee: $205 ** note that prices are subject to change per labor and parts required. |
More Information
Manufacturer | Aeroqual |
---|---|
Gas | Nitrogen Dioxide (NO2) |
Sensor Type | GSE (Gas Sensitive Electrochemical) |
Range | 0-1 ppm |
Maximum Exposure | 2 ppm |
Monitor sensor fits | S-200 / S-300 / S-500, Series-900, Series-930 |
Minimum Detection Limit | 0.005 |
Accuracy | < +/- 0.02 ppm from 0-0.2 ppm; < +/- 10% from 0.2-1 ppm |
Resolution | 0.001 ppm |
Response Time | <30 s |
Sampling Method | Fan |
Operational Temperature Range | 0 to 40 C |
Operational RH Range | 15 to 90 % |
Warranty | 6 Month |