A12 Nitric Oxide Sensor 0-50 ppm (00-0236)
A12 Smart Sensing Modules:
0-50 ppm Nitric Oxide Sensing Module. Smart Sensing Module stores operational information, calibration constants, gas sensor identification and range, and software revision level. This unit can quickly and easily be connected to the A12 UniSens Transmitter.
- SKU
- 00-0236
Description / A12 Nitric Oxide Sensor 0-50 ppm (00-0236)
0-50.0 ppm Hydrogen Sulfide sensor
Standard Range = 0-50 ppm
Minimum Range = 0-25 ppm
Maximum Range = 0-500 ppm
These sensors come ready to operate in any of the above preset ranges (standard, minimum, or maximum). When you connect the Sensing Module to the Gas Transmitter, you will be asked which range you would like to use. We list the standard range as the sensors range, but each sensor is capable of operation in all 3 ranges.
The Sensing Modules consist of an electrochemical gas sensor and solid state memory assembly. This complete package comes in a convenient housing that can easily be connected to the A12 UniSens transmitter. As these sensors come pre-calibrated, once the sensor is connect to the A12 the calibration constants upload to the base automatically. Each sensor can be calibrated to any range within the minimum or maximum range. There is an additional $50 calibration fee for custom calibration.
This Sensing Module is compatible with the A12 Gas Transmitter. If you wish to purchase only the sensors you need 00-0275, but then it will need to be calibrated onsite. You can use the Nitric Oxide Calibration Kit for onsite calibration.
Since the sensors are calibrated independently and simply plug into the A12, you can switch between the 28 different gases offered very quickly and efficiently.
Using the optional sensor keeper you can maintain the sensor in stable operating condition for up to 6 months while it's sitting on the shelf.
All sensors require a yearly calibration to ensure your gas measurements are accurate and performing within manufacturer standards. This page is desiccated to the individual manufacturers we represent and their specific calibration procedures.
**Calibration Service Request Form **
Calibration costs do vary, see below to get an estimate: Calibration Fee: $150 Analyzer Calibration Fee: $300 PM Calibration Sensor Fee: $330 Genie Calibration Fee: $265 ATI Calibration Fee: $205 ** note that prices are subject to change per labor and parts required. |
More Information
Manufacturer | ATI |
---|---|
Gas | Nitric Oxide (NO) |
Sensor Type | Electrochemical Cell |
Accuracy | ± 5% of value |
Standard Range | 0-50 ppm |
Minimum Range | 0-25 ppm |
Maximum Range | 0-500 ppm |
Monitor sensor fits | A12 |
Sensitivity | 1% of sensor module range |
Operational Temperature Range | -30º to +55ºC |
Operational RH Range | 0-95% Non-condensing |
Warranty | 1 Year |