UV Light for Ozone Destruction in Water
UV Light for Ozone Destruction in Water
Using UV Light to Remove Dissolved Ozone from Water
Ozone is widely used for water disinfection, sanitation, and oxidation because it is a powerful oxidizer that leaves no persistent chemical residual. However, there are many applications where ozone is useful during treatment but must be removed from the water before the water reaches the point of use.
Ultraviolet light provides a simple, chemical-free method of destroying residual dissolved ozone.
When ozone-containing water is exposed to 254 nm ultraviolet light waves, the UV energy is absorbed by the ozone and initiates its decomposition. Properly applied and sized UV light systems reduce or eliminate ozone in water without adding another chemical to the water.
What Wavelength of UV Light Destroys Ozone?
The primary wavelength used for dissolved ozone destruction is:
254 nm UV-C
Low-pressure germicidal UV lamps produce most of their useful UV energy near 254 nm. Conveniently, ozone also absorbs UV energy at this wavelength, making conventional low-pressure UV technology useful for ozone destruction.
|
Wavelength |
Function |
|
254 nm |
Destroys dissolved ozone and provides germicidal treatment |
|
185 nm |
Can generate ozone from oxygen |
More information on ozone generation from UV here
For ozone destruction in water, 254 nm is the wavelength of interest.
Ozone-Destruct UV Light vs Standard Germicidal UV Light
A conventional low-pressure germicidal UV lamp commonly operates near 254 nm, the same wavelength useful for destroying ozone.
The difference is UV dose and system sizing.
A UV system designed for disinfection exposes microorganisms to sufficient UV energy to prevent them from reproducing. Destroying a significant concentration of dissolved ozone generally requires substantially more UV exposure or UV dosage.
A UV system's published germicidal flow rating should not normally be used as its ozone-destruction flow rating. The same equipment for both applications is suitable, but it will generally need to operate at a significantly lower flow rate.
Sizing a UV System for Ozone Destruction
As a general preliminary sizing guideline, Oxidation Technologies recommends using approximately:
1/3 of the manufacturer's normal germicidal flow rating
Or:
Ozone Destruction Flow ≈ Germicidal Rated Flow ÷ 3
Example:
A UV system rated for:
30 GPM for germicidal treatment
would have an estimated ozone-destruction flow-rate of:
30 GPM ÷ 3 = approximately 10 GPM
This would achieve approximately 90-95% reduction of ozone in water
For example:
|
Ozone entering UV |
90% destroyed |
95% destroyed |
|
0.20 ppm |
0.020 ppm remaining |
0.010 ppm remaining |
|
0.50 ppm |
0.050 ppm remaining |
0.025 ppm remaining |
|
1.00 ppm |
0.100 ppm remaining |
0.050 ppm remaining |
|
2.00 ppm |
0.200 ppm remaining |
0.100 ppm remaining |
This is a useful equipment-selection guideline, but it should not be treated as a guarantee of a specific outlet ozone concentration.
For critical applications, the system should be evaluated based on:
-
- Water flow rate
- Incoming dissolved ozone concentration
- Required outlet ozone concentration
- UV transmittance (UVT)
- Lamp intensity and age
- Reactor design
- Quartz sleeve condition and fouling
- Water quality
- Safety factor
UV treatment performance is strongly affected by UV transmittance and water chemistry.
Common applications for UV Lights system to remove ozone from water:
UV ozone destruction can be particularly useful when ozone is beneficial during storage, circulation, or sanitation but undesirable at the point of use.
Applications can include:
-
- High-purity water systems
- Pharmaceutical and process water
- Food and beverage processing
- Rinse-water systems
- Bottling applications
- Recirculating sanitation systems
- Aquaculture
- Hydroponic Greenhouses
- Industrial process water
- Water where an ozone residual needs to be removed before use
For example, an ozone-treated storage and distribution loop can maintain an ozone residual during a sanitation cycle. The UV system can then be used to reduce the ozone residual before the water reaches downstream equipment or the point of use.
For examples review the information linked below on the use of ozone and UV in ultra-pure water systems:
https://www.oxidationtech.com/applications/water-treatment/ozone-pure-water.html
AOP Reactions with UV Ozone Destruction
UV does more than simply eliminate ozone. The reaction between ozone, UV energy and water can produce highly reactive hydroxyl radicals (•OH).
This combination is known as a UV/Ozone Advanced Oxidation Process, or AOP. These hydroxyl radicals can oxidize certain organic contaminants that may be more difficult to treat with ozone alone.
Learn more: UV/Ozone Advanced Oxidation Processes (AOP) →
Selecting a UV System for Ozone Destruction
For preliminary selection, determine:
-
- Maximum water flow in GPM
- Expected dissolved ozone entering the UV
- Maximum acceptable ozone concentration leaving the UV
- Water UV transmittance, if available
- Water quality and application
- Whether downstream verification of dissolved ozone is required
For simple applications, the germicidal flow ÷ 3 guideline provides a useful starting point. Applications requiring a guaranteed outlet residual should be evaluated on the basis of actual UV dose and operating conditions.