ATI Chlorine Sensor 0-2 ppm (00-1002)

Smart Sensor Modules:

0-2 ppm Chlorine sensor with a resolution of 0.01 ppm

The ATI Smart Sensor is a versatile, plug-and-play gas detection solution designed for use with the D-16, F-12is, F-12D, and D-12 gas detectors. It allows for quick sensor swaps, making it ideal for industries that require continuous and reliable gas monitoring.

2-3 weeks
SKU
ATI 00-1002
  $422.00

Description / ATI Chlorine Sensor 0-2 ppm (00-1002)

0-2 ppm Chlorine sensor with a resolution of 0.01 ppm

Standard Range = 0-2 ppm

Minimum Range = 0-1 ppm

Maximum Range = 0-5 ppm

These sensors come ready to operate in any of the above-preset ranges (standard, minimum, or maximum).  When you connect the Sensing Module to the Gas Transmitter, you will be asked which range you would like to use.  We list the standard range as the sensors range, but each sensor is capable of operation in all 3 ranges. Sensor modules are ATI's newest miniaturized smart sensor modules.  Each sensor module is actually a sensor, amplifier, and memory module in one compact package.  Because of this design, sensor modules can be calibrated independently and simply plugged into any detector for immediate use.  When installed in a detector, calibration data is loading into the microprocessor so that no adjustments are needed.  The result is that a detector can, for example, go from phosgene measurement to ammonia measurement in less than one minute. Using the optional sensor keeper allows up to 4 sensors to be powered by the internal sensor keeper battery and keep sensors ready for use.  This ensures maximum accuracy in the shortest time frame possible.

The ATI Smart Sensors are compatible with the D-16, F-12is, F-12D, and D-12 gas detectors.

All smart sensors are constructed of glass filled polycarbonate and use an electrochemical cell for gas detection.

 

Calibration Services:

All sensors require a yearly calibration to ensure your gas measurements are accurate and performing within manufacturer standards. These sensors are constructed of glass filled polycarbonate and use an electrochemical cell for gas detection The ATI Chlorine 0-2 ppm (00-1002) sensor has a detection range of 0-2 ppm, so the calibration gas you use must fall within this range. Refer to the table below for our recommended calibration gas options.

Product Range Price
C18-11 Chlorine Gas Generator
C18-11 Chlorine Gas Generator
$312.00
C18-11 Chlorine Gas Generator

C18-11 Chlorine Gas Generator

$312.00

Range

View Details

 

 

 

More Information

Manufacturer ATI
Gas Chlorine (Cl2)
Sensor Type Electrochemical Cell
Range 0-2 ppm
Maximum Exposure 0-5 ppm
Minimum Detection Limit 0-1 ppm
Accuracy ± 5% of value
Resolution 0.01 ppm
Standard Range 0-2 ppm
Minimum Range 0-1 ppm
Maximum Range 0-5 ppm
Monitor sensor fits D16 / C16 / F12 / D12
Sensitivity 1% of sensor module range
Operational Temperature Range -25º to +55ºC
Operational RH Range 0-95% Non-condensing
Warranty 1 Year

We found other products you might like!

Navigating through the elements of the carousel is possible using the tab key. You can skip the carousel or go straight to carousel navigation using the skip links.
D16 PortaSens III Gas Detector
As low as $1,589.00