Sample Conditioner Used
Sample Conditioner Used
The Sample Conditioner eliminates moisture from ozone sample lines, ensuring reliable readings and protecting ozone analyzers from humidity interference.
Condition: Used Like-New
New Option HERE
- SKU
- Sample_conditioner-Used
Description / Sample Conditioner Used
The Sample Conditioner is an engineered moisture-management system designed to ensure accurate and stable ozone measurements in industrial processes.
Perfect for applications where the sample gas humidity is high, or where temperature changes may cause condensation in the UV Ozone Analyzer
Even small amounts of water vapor or condensate can cause false readings, sensor drift, or complete analyzer failure.
Common Applications:
- High humidity applications where moisture in the sample lines has any condensation potential
- Off-gas applications, where ozone gas is pulled from the headspace or off-gas from ozone water systems
- Treatment chambers/rooms with elevated temperatures, the sample gas will cool and potentially condense
- Treatment chambers/rooms with elevated humidity
- Any applications where moisture may condense in the ozone gas sample line
The Sample Conditioner uses 316 stainless steel tubing and a stainless steel water trap, moisture drain. All 316 stainless steel materials are used in the ozone sample gas line to eliminate ozone reactions in the sample conditioner. This maintains consistant ozone levels and accurate readings of ozone levles by the ozone analyzer after the Sample Conditioner.
Ozone Analyzer Sample Conditioner:
The Diagram below illustrates the sample conditioner's internal flow path and operation.
Ozone Analyzer Sample Conditioner in Use:
The Diagram below illustrates the sample conditioner in use.
Ozone Analyzer Filter Housing:
We suggest adding a sample line filter prior to the sample conditioner to eliminate dust, and particles that may contaminate either the sample conditioner or ozone analyzer.
More Information
| Manufacturer | Oxidation Technologies |
|---|---|
| Listing Description |
|
| Unit Features | The Sample Conditioner eliminates moisture from ozone sample lines, ensuring reliable readings and protecting ozone analyzers from humidity interference. Gas Flow Rate 0.1 - 10 LPM. Poower Requirements 120 VAC |
| Nominal Gas Flow Rate | 0.1 - 10 LPM |
| Operating Pressure | -5 PSI Vacuum - 20 PSI pressure |
| Max Pressure | 20 PSI Pressure |
| Gas Connections | 1/4" Female NPT |
| Dimensions (LxWxH) | 8" wide x 18" tall x 6" deep |
| Operational Temperature Range | 0 - 105-deg F |
| Power Requirements | 120 VAC |
| Lead Time | 2 weeks |
| Warranty | 1 Year |
| Country of Origin | USA |