phone Contact Us

Ozone Applications

Aircraft Water Disinfection AOP Agri-Food Processing Air Treatment Ammonia Removal From Water Aquaculture Aquatic Life Support Systems Beef (Red Meat) Processing with Ozone Biological Oxygen Demand Bottled Water Cannabis Car Wash Water Reclaim Systems Case Studies Case Studies: Force Main Treatment Case Study: Enhancing Fish Processing with Ozone Technology in Georgetown, Guyana Case Study: Ozone Water Disinfection System for Major U.S. Airline Case Study: Spice Warehouse Ozone Installation Chemical Oxygen Demand (COD) Removal with Ozone Clean In Place (CIP) Concrete Cooling Tower Cyanobacteria and Toxin Removal with Ozone Dairy Farms Drinking Water E.coli O157:H7 Reduction with Ozone Flour Milling Force Main Treatment Grain Treatment Groundwater Remediation Hydroponic Greenhouses Lake Remediation Laundry Listeria Inactivation with Ozone Machine Coolant Tanks Municipal Water Treatment NOx removal with Ozone Nanobubbles Odor Control with Ozone Odor Removal Oxidize Tannins from Water with Ozone Ozonated Ice & Fish Storage Ozone Applications in Mining Industry Ozone Regulations in Food Processing Ozone Regulations in Organic Food Production Ozone for Mold Elimination Ozone in Air Applications Ozone in Seafood Processing Ozone use for Post-Harvest Processing of Berries Ozone use in Wet Scrubbers Ozone-Biofiltration Plastic Adhesion Pool & Spa Pork Processing with Ozone Resolution Concerning the Use of Ozone in Food Processing Shellfish Depuration Surface Sanitation Ultra-Pure Water Vertical Farming with Ozone Waste Water Treatment Water Re-use Water Treatment Well Water Treatment

Correct flow for flow-meter


Corrected pressure for pressurized flow meter

Measured Flow
Pressure in PSI
Corrected Flow Rate

Corrected Flow = Measured flow X √ (PSI +14.7) / 14.7 

Calculate pressure in your float style flow-meter using this calculation. When flow-meters are under pressure the flow must be calculated for the pressure to provide accurate flow readings.

 

About this calculator:

Use this calculator to correct gas flow reading from a standard float style flow-meter for pressure. Standard flow-meters will read an artificially low value when under pressure and will give an artificially low flow reading when under pressure. This calculator will correct for pressure and give an accurate reading.

Any flow unit can be used (LPM, SCFH, etc.) as the calculator is calculating for pressure. Therefore input your flow value and pressure value without concern over unit of measure for flow.

This calculator uses PSI for pressure readings only. You have have to convert your pressure reading to PSI.

 

Convert PSI using calculator below:


Pressure Calculator

PSI
Bar
Feed of Head
Torr

Convert any pressure value by entering value in the blank and pressing Convert.



 

Helpful Links:

-Ozone Dosage Rate Calculator HERE

-Calculate ozone generator output from g/m3 ozone concentration

-Calculate ozone generator output from % by weight ozone concentration

-Calculator to convert common ozone concentration units

-Ozone output units conversion calculator

-Calculator to convert common flow measurements

-Calculate flow in a pressurized flow-meter

-Other common units of measure HERE

-Other common ozone calculations HERE

 

Questions on your ozone application?  Call us, we enjoy discussing ozone applications and hope to help you find success in every ozone installation.