- Benchmount Enclosure - Accuracy = 2% of reading - Low power draw; can be battery-operated (12 VDC) - Integrated datalogging - Benchmount Enclosure - Accuracy = 1.5 ppb or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - FEM: EQOA-0914-218 -Benchmount enclosure -Accuracy = 1.5 ppb or 2% of reading - DewLine™ for Humidity Control - SD Card for portable data storage - FEM: EQOA-0410-190 - Benchmount Enclosure - Accuracy = 1.0 ppb or 2% of reading - Dual beam optical bench - SD Card for portable data storage - DewLine™ for Humidity Control - FEM: EQOA-0410-190 - Industrial Enclosure, Water Resistant - Accuracy = 1.5 ppb or 2% of reading - Multi-channel options available - DewLine™ for Humidity Control - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Rugged design, simple maintenance - Minimal zero drift - Multi-channel options available Customizable: 0-500 ppm -Bench Mount -Rugged and lightweight chassis with handle -Quiet and easy to use -SD Card for portable data storage Unit Features - Benchmount Enclosure - Accuracy = 2% of reading - Low power draw; can be battery-operated (12 VDC) - Integrated datalogging Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 1.5 ppb or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - FEM: EQOA-0914-218 Range Resolution Unit Features -Benchmount enclosure -Accuracy = 1.5 ppb or 2% of reading - DewLine™ for Humidity Control - SD Card for portable data storage - FEM: EQOA-0410-190 Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 1.0 ppb or 2% of reading - Dual beam optical bench - SD Card for portable data storage - DewLine™ for Humidity Control - FEM: EQOA-0410-190 Range Resolution Unit Features - Industrial Enclosure, Water Resistant - Accuracy = 1.5 ppb or 2% of reading - Multi-channel options available - DewLine™ for Humidity Control Range Resolution Unit Features - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Rugged design, simple maintenance - Minimal zero drift - Multi-channel options available Range Customizable: 0-500 ppm Resolution Unit Features -Bench Mount -Rugged and lightweight chassis with handle -Quiet and easy to use -SD Card for portable data storage Range Resolution
Product
Unit Features
Range
Resolution
Price
0-999 ppm
0.01 ppm
Call For Price
0-20 ppm
0.1 ppb
0-20 ppm
0.1 ppb
0-20 ppm
0.1 ppb
0-20 ppm
0.1 ppb
1 ppb
0-20,000 ppb
16-Bit
UV-100
UV-106-L
Model 202
Model 205
UV-106L-NEMA
465L
430
- Benchmount Enclosure - Accuracy = 0.01 ppm or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - Benchmount Enclosure - Accuracy = 0.05 ppm or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - Industrial Enclosure, Water Resistant - Accuracy = 0.05 ppm or 2% of reading - Multi-Channel options avaialble - DewLine™ for Humidity Control - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Customizable ranges for suburb acuracy - Minimal zero drift - Multi-channel options available Customizable: 0-10,000 ppm 0-3 wt% - Industrial Enclosure, Water Resistant - Accuracy = 0.01 ppm or 2% of reading - Multi-Channel options available - DewLine™ for Humidity Control Unit Features - Benchmount Enclosure - Accuracy = 0.01 ppm or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 0.05 ppm or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control Range Resolution Unit Features - Industrial Enclosure, Water Resistant - Accuracy = 0.05 ppm or 2% of reading - Multi-Channel options avaialble - DewLine™ for Humidity Control Range Resolution Unit Features - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Customizable ranges for suburb acuracy - Minimal zero drift - Multi-channel options available Range Customizable: 0-10,000 ppm 0-3 wt% Resolution Unit Features - Industrial Enclosure, Water Resistant - Accuracy = 0.01 ppm or 2% of reading - Multi-Channel options available - DewLine™ for Humidity Control Range Resolution
Product
Unit Features
Range
Resolution
Price
0-1,000 ppm
0.01 ppm
0-10,000 ppm
0.1 ppm
0-10,000 ppm
0.1 ppm
0.001 ppm
0-1000 ppm
0.01 ppm
UV-106-M
UV-106-MH
UV-106MH-NEMA
465M
UV-106M-NEMA
- Benchmount Enclosure - Accuracy = 0.01 wt% or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Rugged design, simple maintenance - Customizable ranges for supurb accuracy - Minimal zero drift - Multi-channel options available Customizable: 0-25 wt% 0-400 wt% - Industrial Enclosure, Water Resistant - Accuracy = 0.01 wt% or 2% of reading - Multi-channel options available - DewLine™ for Humidity Control Unit Features - Benchmount Enclosure - Accuracy = 0.01 wt% or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control Range Resolution Unit Features - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Rugged design, simple maintenance - Customizable ranges for supurb accuracy - Minimal zero drift - Multi-channel options available Range Customizable: 0-25 wt% 0-400 wt% Resolution Unit Features - Industrial Enclosure, Water Resistant - Accuracy = 0.01 wt% or 2% of reading - Multi-channel options available - DewLine™ for Humidity Control Range Resolution
Product
Unit Features
Range
Resolution
Price
0-20 wt%
0.01 %
0.01 %
0-20 wt%
0.01 %
UV-106-H
465H
UV-106H-NEMA
- OEM Mounting, no display - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Minimal Zero drift - Low power draw (15 VDC) Customizable 0-25 wt% 0-500 g/m3 - Board-level mounting - Accuracy = 1.5ppb or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface - Board-level mounting - Accuracy = 0.01 ppm or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface - Board-level mounting - Accuracy = 0.01 wt% or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface - Board-level mounting - Accuracy = 0.1 ppm or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Unit Features - OEM Mounting, no display - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Minimal Zero drift - Low power draw (15 VDC) Range Customizable 0-25 wt% 0-500 g/m3 Resolution Unit Features - Board-level mounting - Accuracy = 1.5ppb or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Range Resolution Unit Features - Board-level mounting - Accuracy = 0.01 ppm or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Range Resolution Unit Features - Board-level mounting - Accuracy = 0.01 wt% or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Range Resolution Unit Features - Board-level mounting - Accuracy = 0.1 ppm or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Range Resolution
Product
Unit Features
Range
Resolution
Price
0.01 %
0-20 ppm
0.1 ppb
0-1,000 ppm
0.01 ppm
0-20 wt%
0.01 %
0-10,000 ppm
0.1 ppm
Model 452
UV-106L OEM
UV-106M OEM
UV-106-H OEM
UV-106MH-OEM
-Calibrate Any Ozone Monitor -Autocalibration Scheduler -Easy-To-Use Menu Unit Features -Calibrate Any Ozone Monitor -Autocalibration Scheduler -Easy-To-Use Menu Range Resolution
Product
Unit Features
Range
Resolution
Price
30-1000 ppbv
2 ppbv
Model 306 Ozone Calibration Source
- Interference free measurement of dissolved ozone in ultrapure or "dirty" water - NEMA water-proof housing - Records measurement every 10 seconds - Internal data logger logs 16,383 lines of data - Precision and accuracy of 0.05 ppm or 1% of reading - Both serial and user-scalable analog outputs (0-2.5V and 4-20mA) - Selectable data averaging times of 10 seconds, 1 minute, 5 minutes, and 1 hour Unit Features - Interference free measurement of dissolved ozone in ultrapure or "dirty" water - NEMA water-proof housing - Records measurement every 10 seconds - Internal data logger logs 16,383 lines of data - Precision and accuracy of 0.05 ppm or 1% of reading - Both serial and user-scalable analog outputs (0-2.5V and 4-20mA) - Selectable data averaging times of 10 seconds, 1 minute, 5 minutes, and 1 hour Range Resolution
Product
Unit Features
Range
Resolution
Price
0 - 100 ppm
0.1 ppm
Call For Price
UV-106-W Aqueous Ozone Monitor
Rental Period Rental Period
Product
Rental Period
Price
Weekly
Weekly
UV-106-L Ozone Analyzer Rental
UV-106-M Ozone Analyzer Rental
Ozone Monitor Information:
|
We offer additional gas detection products in partnership with our subsidiary, Gas Sensing. For gasses other than ozone view the Gas Sensing website. |
3 Items